Operating the DXL5000 3-11
DXL5000 User and Technical Manual
3.6.2
Modifying Alarm Settings (Alarms Tab)
Alarms have a default severity and type, but you can modify the severity and type of alarm by
clicking on the
Configure
button next to any alarm on the
Alarms—Information
screen.
Clicking the
Configure
button displays a settings window similar to the following figure.
Severity
CAUTION
Disabling an alarm can have serious consequences to the system and
performance.
Type
Latch
Trigger
Relay
Causes a summary alarm to occur, a front-panel LED to light, and in the case of a
transmitter, disables the power amplifier (PA).
Indication
Causes a front-panel LED to light when an alarm condition exists.
Disabled
Ignores the alarm condition.
Major Alarm
Flashing red LED indicates a Trigger Relay condition; steady red LED indicates an
indication condition.
Minor Alarm
Solid Amber indicates an alert condition is present; green indicates no alert.
On
Hold the alarm until you acknowledge it by manually resetting it.
Off
Do not hold the alarm; if the condition is corrected, the alarm resets itself.