background image

VP-4 Pager – Programming User Guide – Version 1.01 

 

1

VP-4 Pager – Programming User Guide  

 

Note

: The section below applies to pagers labeled with 

8108-V4

 or later versions. For previous versions, please refer to page 3. 

 

Manual Programming Mode 

 

The manual programming provides access to the settings of 6 capcodes, baud rate, frequency and data polarity. 
 
1.

 

Insert a battery and turn on the pager. 
 

2.

 

a. Press the 

 key until the graphic menu is displayed. 

b. Press the 

 key until the display shows 

ON/OFF PAGER

c. Press the 

 key to turn off the pager. 

 

3.

 

Press and hold both the 

 and 

 keys until the password screen is displayed. 

 

4.

 

Enter the password. Use the 

 

key to select a digit and press 

 key to navigate to the next password digit. After the 4th digit 

was entered, press the 

READ/ON-OFF 

key. 

 

Note

: Default password is 

1141

 
 

Changing Capcodes 

 
1.

 

Enter the manual programming mode as described in the Manual Programming Mode section. The display will show 

ABFLPq

 

2.

 

a. Verify that the 

A

 field is underlined or use the 

 key to navigate the cursor to the 

field. 

b. Press the 

READ/ON-OFF

 key. 

 

3.

 

The display will show “

1:

 

CCCCCCC

 

0 P

”, where CCCCCCC is the capcode already programmed in to the pager. 

The first digit label represents the number of the capcode (capcode ID) to be edited. For example, 1 represents capcode #1 and 6 
represents capcode #6. 
 

4.

 

Select the ID of the capcode to be edited using the

 

 key. 

 

5.

 

Press the 

 

key. The cursor will move to the 

CAPCODE

 field. 

 

6.

 

a. Use the 

 

key to enter a respective capcode digit for each underlined digit in the capcode field. 

b. Press the 

 

key to navigate to the next digit. 

c. After the rightmost digit was entered, press the 

 

key. The cursor will move to the 

ON/OFF

 field. 

 
Note

: Standard capcode range is from 0000008 to 2097151. Invalid capcodes will be rejected. 

 

7.

 

a. Use the 

 

key to toggle between 

1

 (ON) and 

0

 (OFF) for the selected capcode. If you wish the capcode to be active, select 

1

 

(ON). 

b. Press the 

 

key. The cursor will move to the 

TYPE

 field 

 

8.

 

Use the 

 

key to toggle between 

P

 (PERSONAL) and 

M

 (MAILDROP) for the selected capcode. Recommended value is 

P

 

9.

 

Press the 

 

key. The cursor will move to the capcode ID field. 

 

10.

 

 To program additional capcodes, press the

 

 key to select the capcode to be programmed and repeat steps 5-8 for each 

capcode. Otherwise, press the 

READ/ON-OFF 

key to return to the main programming menu. 

 

11.

 

 a. If additional programming is not required, press the 

 

key until the cursor is under the 

q

 field. 

 b. Press the 

READ/ON-OFF

 key to exit the programming mode and return to standard operation mode. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание VP-4

Страница 1: ...o the pager The first digit label represents the number of the capcode capcode ID to be edited For example 1 represents capcode 1 and 6 represents capcode 6 4 Select the ID of the capcode to be edited using the key 5 Press the key The cursor will move to the CAPCODE field 6 a Use the key to enter a respective capcode digit for each underlined digit in the capcode field b Press the key to navigate ...

Страница 2: ...y programmed in to the pager 4 a Use the key to enter a respective frequency digit for each underlined digit in the frequency field b Press the key to navigate to the next programmable digit c After the rightmost digit was entered press the key The cursor will return to the first available frequency digit Note The frequency must be within the frequency band supported by the pager refer to the labe...

Страница 3: ...CCCC is the capcode already programmed in to the pager The first digit label represents the number of the capcode capcode ID to be edited For example 1 represents capcode 1 and 6 represents capcode 6 4 Select the ID of the capcode to be edited using the key 5 Press the key The cursor will move to the CAPCODE field 6 a Use the key to enter a respective capcode digit for each underlined digit in the...

Страница 4: ...o June 2011 or for non standard frequency ranges If the FR field in not displayed on the pager s programming menu the manual frequency programming feature is not supported by the pager VHF pagers may not support manual frequency modification although FR field is displayed In that case the pager will have to be sent back to Visiplex for reprogramming or the frequency may be changed using an optiona...

Отзывы: