Vision ZS 6101 IN Скачать руководство пользователя страница 3

 

 

 

 

 

Operation 

 

1. 

Power-on Mode: 

1) Install the battery into the module 2) Close the bracket 3) the 

detector  will  take  8  to  12  sec.  and  emit  a  beep  to  confirm  and  start  the  burglar 
system. The detector will alarm once remove the bracket. 

2. 

STANDBY  MODE: 

The  red  LED,  as  the  ALARM  indicator,  are  featured  with  the 

smoke alarm. It can be seen through the clear test button on the cover of the unit. 
When  red  LED  flashes  once  334  seconds,  it  indicates  the  smoke  alarm  is  under 
normal  operation.  When  smoke  alarm  senses  smoke  and  simultaneously  sounds 
an  audible  alarm  with  3  beeps,  pause  and  3  beeps.  The  red  LED  will  flash 
continuously and rapidly. 

3. 

SILENCE FEATURE:

 

The silence feature can temporarily quite an alarm for up to 

10  minutes.  To  use  this  feature,  press  test  button  on  the  cover  when  it  alarms. 
However, if the smoke concentration around the smoke alarm unit is still at alarming 
level after 10 minutes of silence, the unit will re-alarm immediately. 

4. 

LOW BATTERY WARNING SIGNAL:

 

If the alarm horn begins to chirp once in 43 

seconds with red and yellow LED flashing, this signal means that the smoke alarm’s 
battery is weak. This low battery warning signal should last for up to 30 days, but 
you should replace the battery immediately to secure your protection.   

5. 

TAMPER SWITCH FEATURE:

 

If the smoke alarm is not mounted into the bracket 

properly within 5 minutes after battery is installed, the tamper function is triggered 
and the Yellow LED is steadily on. If the smoke alarm is still not mounted into the 
bracket  properly  5  minutes  after  battery  is  installed,  you  will  hear  temporal  three 
sound with yellow LED steadily on until smoke alarm is mounted back into bracket 
properly.   

6. 

MALFUNCTION (ERROR) SIGNAL:

 

If you hear 3 “beep” with yellow LED flashing 

3  times  in  43  seconds,  it  indicates  that  the  smoke  alarm  does  not  work  properly, 
please have it repaired or serviced. 

7. 

TESTING YOUR SMOKE ALARM

 

Test the alarm weekly by pushing firmly on the 

test button with your finger for around 4 seconds until the horn sounds, the sound 
pattern  is  3  beeps  ,  pause,  and  then  3  beeps  with  red  LED  flashing  continuously 
and rapidly.If the smoke alarm beeps three with yellow LED flashing three times in 
43 seconds, it indicates the smoke alarm is not working properly, it requires to be 
repaired  or serviced

.   

Then,  the smoke  detector  will  send  an  alarm  report  (Alarm 

type: 0x01, Level: 0xFF) to the user’s controller and also the dectecor will send an 
alarm report (Alarm type: 0x01, Level: 0x00) while the alarm off. 

 

 

8. 

Battery  Power  indicator:

 

The  detector  will  report  the  current  status  of  battery 

capacity to the user

’s contorller. 

9. 

Self-Protection Mode:

 

If the detector removed from bracket, the detector will send 

an alarm sensor (Alarm type:0x01, level:0xFF) to the Z-Wave Interface Controller , 
and the Yellow LED will on contiuously and the detector will sound. 

    Federal Communications Commission Statement 

 

This equipment has been followed to comply with the limits for a Class B digital device, pursuant to 
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful 
interference in a residential installation. This equipment generates, uses and can radiate radio 
frequency energy and, if not installed and used in accordance with the instruction, may cause harmful 
interference to radio communications. However, there is no guarantee that interference will not occur 
in a particular installation. If this equipment does cause harmful interference to radio or television 
reception, which can be determined by turning the equipment off and on, the user is encouraged to try 
and correct the interferene by one of the following measures: 
-- Reorient or relocate the receiving antenna, 
-- Increase the separation between the equipment and receiver, 
-- Connect the equipment into and outlet on a circuit different from that to which the receiver is 
connected. 
-- Consult the dealer or an experienced radio/TV technician for help. 
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two 
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any 
interference received, including interference that may cause undersired operation. 
FCC Caution: Any changes or modifications not expressly approved by the party responsible for 
compliance could void the user

’s authority to operate this equipment

 

Limited Warranty 

 

Vision Guarantees that every wireless smoke detector is free from physical defects in 
material and workmanship under normal use for one year from the date of purchase. If 
the product proves defective during this one-year warranty period, Vision will replace it 
free of charge. Vision does not issue any refunds. This warranty is extended to the 
original end user purchase only and is not transferable. This warranty does not apply to: 
(1) damage to units caused by accident, dropping or abuse in handling, or any negligent 
use; (2) units which have been subject to unauthorized repair, opened, taken apart, or 
otherwise modified; (3) units not used in accordance with instruction; (4) damages 
exceeding the cost of the product; (5) transit damage, initial installation costs, removal 
cost, or reinstallation cost. 
For information on addional devices, plesae visit us at www.visionsecurity.com.tw 

 

 

 

 

 

 

 

                       