Vision ZF 5201 IN-5 Скачать руководство пользователя страница 1

Operation

 

 

1. 

While detecting water, the sensor will be triggered and send signal to your controller.

 

2. 

Normal operation, the LED will not light. 

 

3. 

If the cover of sensor is removed, the tamper switch will send signal according the 
Status/Signal  table,  and  the  LED  will  go  solid.    Before  replacing  the  cover,  the 
sensor is under 

“Awake” mode.

 

4. 

Support  OTA Firmware  update  from  the controller.    Please  refer  to  your  controller 
manual.

 

5. 

Triger  the  Water  Sensor  10  times  within  10  sec.    The  device  will  send  command 
class of device reset to controller and back to the factory default state.    Please use 
this  procedure  only  in  the  event  that  the  network  primary  controller  is  missing  or 
otherwise inoperable.

 

Federal Communications Commission Statement 

This equipment has been followed to comply with the limits for a Class B digital device, 
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable 
protection  against  harmful  interference  in  a  residential  installation.  This  equipment 
generates, uses and can radiate radio frequency energy and, if not installed and used in 
accordance with the instruction, may cause harmful interference to radio communications. 
However, there is no guarantee that interference will not occur in a particular installation. 
If this equipment does cause harmful interference to radio or television reception, which 
can be determined by turning the equipment off and on, the user is encouraged to try and 
correct the interferene by one of the following measures: 

-

 

Reorient or relocate the receiving antenna, 

-

 

Increase the separation between the equipment and receiver, 

-

 

Connect  the  equipment  into  and  outlet  on  a  circuit  different  from  that  to 
which the receiver is connected. 

-

 

Consult the dealer or an experienced radio/TV technician for help. 

This device complies with Part 15 of the FCC Rules. Operation is subject to the following 
two  conditions:  (1)  this  device  may  not  cause  harmful  interference,  and  (2)  this  device 
must accept any interference received, including interference that may cause undersired 
operation. 
FCC  Caution:  Any  changes  or  modifications  not  expressly  approved  by  the  party 
responsible for compliance could void the user

’s authority to operate this equipment. 

Limited Warranty 

Vision  Guarantees  that  every  flood  sensor  is free  from  physical  defects  in material  and 
workmanship  under  normal  use  for  one  year  from  the  date  of  purchase.  If  the  product 
proves defective during this one-year warranty period, Vision will replace it free of charge. 
Vision  does  not  issue  any  refunds.  This  warranty  is  extended  to  the  original  end  user 
purchase  only  and  is  not  transferable.  This  warranty  does  not  apply  to  :  (1)  damage  to 
units caused by accident, dropping or abuse in handling, or any negligent use; (2) units 
which  have  been  subject to  unauthorized  repair,  taken  apart,  or  otherwise  modified;  (3) 
units  not  used  in  accordance  with  instruction;  (4)  damages  exceeding  the  cost  of  the 
product;  (5) transit  damage,  initial  installation  costs,  removal cost, or  reinstallation  cost. 
For information on addional devices, plesae visit us at 

www.visionsecurity.com.tw

 

 

 

 

 

ZF5201-5  V1 

1040515 

6B1Z-52002 

 

 

 

 

 

 

 

 

Installation & Operation Manual 

 

 

ZF 5201 IN-5 

ZF 5201 MY-5 

ZF 5201 EU-5 

ZF 5201 RU-5 

ZF 5201 US-5 

ZF 5201 IL-5 

ZF 5201 KR-5 
ZF 5201 HK-5 

ZF 5201 JP-5 

ZF 5201 BR-5 

 
 
 