![Vision Components VC Smart Camera Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/vision-components/vc-smart-camera/vc-smart-camera_getting-started_1031724019.webp)
Getting Started VC Smart Cameras
15
4.6.3
The default Compiler settings are:
The advanced compiler setting “-mi100000” sets the interrupt threshold to 100,000 cycles, defining the
maximum frequency interrupts are queried. Omitting this setting can speed up some functions
significantly. However in this case it is important to ensure that inner loops perform less than 100,000
cycles, as interrupts (e.g. timer) can be out of sync otherwise. The “
Code Optimization
” document,
part of the “Advanced Programming Seminar” covers the speed optimization of programs in detail
(download under:
Service & Support Download Center Documentation VC Seminars
)
.
4.6.4
The default linker settings are:
From PC Library Version VCRT 5.18 the linker setting “-u_c_int01” is required (also refer to the
following section for setting changes).
1996-2011 Vision Components GmbH Ettlingen, Germany