A-DIF-90x120-W5K7-SL
Technical Data
5.2 Electrical Parameters
NOTICE
If the lighting is operated by using power sources of other manufacturers,
verify that temperature, current and pulse time have to be kept inside
specified limits! Please refer to the diagram:
.
There is no automatic limitation of the electrical parameters. The temperature
of the device is not monitored automatically.
Parameter
Min
Nom
Max
Continuous operation
LED current I
LED
2.1 A
(1)
4.8 A
(2)
Forward voltage U
LED
at I
LED Max
5.4 V
6.8 V
Power consumption P
tot
12.0 W
(1)
Flash mode / Pulse mode
LED current I
LED
20.0 A
(2),(3)
Forward voltage U
LED
at I
LED Max
7.3 V
8.7 V
Flash performance P
flash
150.0 W
(2),(3)
(1)
The nominal values refer to an ambient temperature of 25 °C and free
convection.
(2)
Maximum power of the lighting (maximum current) is achieved at optimal
heat dissipation only.
(3)
Error-free operation is only guaranteed in combination with vicolux
smart light controllers. The controller limits the electrical parameters
automatically and also monitors the temperature of the device.
18
999.995.569.10-en-1.0
© Vision & Control GmbH 2019