background image

SLE-150-W5K7-P-24V

Operation

7.1 Making Operational Readiness

The device is switched on by applying the operating voltage.
The device is switched off by disconnecting it from the operating voltage

supply.

7.2 Operating Modes

The integrated controller supports the following operating modes:

Continuous operation

Switching operation

Continuous operation

The lighting is switched on by setting the ON/OFF signal after the delay time t

d

.

Resetting the ON/OFF signal turns off the lighting.

Switching operation

The switching operation is carried out by continuously setting and resetting the

switching signal ON/OFF.
Consider the switching delay time t

d

 of the lighting. Set the exposure time of the

camera to be within the t

ON

 range.

The length of the Power-on time t

ON

 corresponds to the length of the switching

signal.

© Vision & Control GmbH 2021

999.995.383.10-en-1.3

21

Содержание 1-33-311

Страница 1: ...TROL Instructions for Use SLE 150 W5K7 P 24V Compact spot light Colour temperature White 5700 K Instructions for Use SLE 150 W5K7 P 24V Compact spot light Colour temperature White 5700 K 999 995 383 1...

Страница 2: ...this document on to third parties reproduce and communicate its contents in as far as this has not been expressly authorized Offenders will be liable for damages All rights are reserved with respect...

Страница 3: ...dentification Designation Description SLE Compact spot light Attachment optics with condenser lens High energy efficiency 150 Luminous field diameter in mm at 200 mm Working distance W5K7 Colour tempe...

Страница 4: ...ion 12 4 1 Device Views 12 4 2 Notices on the device 13 5 Technical Data 14 5 1 General Parameters 14 5 2 Electrical Parameters 15 5 3 Photometric Parameters 15 5 4 Conditions for Operation Storage an...

Страница 5: ...future reference 1 1 Intended Use The device is intended exclusively for use as a lighting element for industrial image processing in automation technology The device is not suitable for use in potent...

Страница 6: ...ns of use Using spare parts which are not original parts from the manufacturer Using incompatible accessory components Improper maintenance and repair works Unauthorised modifications to the device 1...

Страница 7: ...al and rejects any warranty derived therefrom Within the bounds of the legal requirements the manufacturer shall only be responsible for the technical safety characteristics of the device if the maint...

Страница 8: ...es of the danger These measures must be taken DANGER Indicates an imminent danger with high risk resulting in severe injuries or death if not avoided WARNING Indicates a hazardous situation with mediu...

Страница 9: ...instructions are referred to separately at the relevant points in this manual WARNING Possibly hazardous optical radiation emitted from this product May be harmful to the eye In case of operation do n...

Страница 10: ...V 1 x 3 2 Accessories Connection cable M8 4 pin straight plug 4A 60V Designation Description Order no Connection cable M8 4pin 10m Connection cable with 4 pin M8 socket and open cable end with ferrule...

Страница 11: ...12 Connection cable M8 4pin 3m 1 11 613 Connection cable M8 4pin 5m Connection cable with 4 pin M8 socket and open cable end with wire end ferrules 4 x 0 5 mm 5A 30V PUR IP67 straight plug 1 11 614 DI...

Страница 12: ...ce Views 1 4 4 2 3 4 4 5 1 4 4 6 4 4 5 Image 1 Device view 1 Casing 2 Light emitting surface 3 Filter thread M28x0 5 depth 5 mm 4 Mounting hole M3x0 5 depth 4 5 mm 5 Mounting hole 4 2 through bore 6 C...

Страница 13: ...cription 4 2 Notices on the device Following instructions are provided on the device Type XXXXXXXXX No TTTJJNNN 3 1 2 1 Notes on power supply 2 Device designation 3 Serial number Vision Control GmbH 2...

Страница 14: ...ace Diameter 24 mm Filter thread M28 x 0 5 depth 4 5 mm Connector Male connector M8 4 pin Weight 68 5 g Degree of protection IP 50 Safety class Class III safety extra low voltage SELV Risk group DIN E...

Страница 15: ...tch input ON OFF Input delay tD 50 s 100 s 150 s 5 3 Photometric Parameters Parameter Min Nom Max Colour temperature 5 700 K Colourimetric locus x 0 3287 y 0 3425 Full beam angle 2 40 Luminous field d...

Страница 16: ...ve the specified ambient conditions when transporting and storing the device For accessories connected devices and components observe the specific information in the associated instructions for use Am...

Страница 17: ...1 2 3 4 5 1 2 3 4 5 A A B B C C D D 32 30 8 5 10 11 5 5 75 2 x M3 depth 4 5 mm on both sides 8 5 10 M8 connector 10 11 5 75 2 x M3 depth 4 5 mm 10 11 54 32 light emitting surface 26 mm M28x0 5 depth 4...

Страница 18: ...out the tucked in sides on the bottom of the cardboard The film loosens and forms an insertion pocket 3 Remove the device out of the insertion pocket 4 Dispose the packing material 6 2 Mounting the De...

Страница 19: ...cification see data sheet 6 3 1 Pin assignment Use the M8 connector to connect the device according to the pin assignment Pin assignment 1 2 3 4 Image 5 M8 connector 4 pin Connection diagram V GND 1 3...

Страница 20: ...izures Avoid exposure to certain kinds of flashing lights or stroboscopes Wear protective goggles If you have a known history of epilepsy do not work or stay in areas where there are flashing lights o...

Страница 21: ...Continuous operation The lighting is switched on by setting the ON OFF signal after the delay time td Resetting the ON OFF signal turns off the lighting Switching operation The switching operation is...

Страница 22: ...t Lighting t Switching signal Continuous operation td td td td tON tON ts ts Switching operation ts Exposure time of the camera td Delay time tON Power on time Min Nom Max Delay time td 50 s 100 s 150...

Страница 23: ...leaning the optical surfaces NOTICE Follow the specified cleaning sequence Never use dry cloths for cleaning This allows dust and other contaminants to be rubbed into the lens surface thereby damaging...

Страница 24: ...lad to be of service Monday to Thursday 8 00 to 17 00 and Friday 8 00 to 15 00 Vision Control GmbH Mittelbergstra e 16 98527 Suhl Germany Phone 49 0 3681 7974 0 www vision control com Defective device...

Страница 25: ...eparately and sent to environmentally compatible recycling Disposal including that of individual components must also always be in a way that does not harm the environment which means it must be done...

Страница 26: ...ial environments DIN EN IEC 61000 6 4 2020 09 Electromagnetic compatibility EMC Emission standard for industrial environments DIN EN 61000 4 2 2009 12 Electromagnetic compatibility EMC Testing and mea...

Страница 27: ...SLE 150 W5K7 P 24V Vision Control GmbH 2021 999 995 383 10 en 1 3 27...

Страница 28: ...Vision Control GmbH Mittelbergstra e 16 98527 Suhl Germany Telephone 49 0 3681 7974 0 Telefax 49 0 3681 7974 33 Vision Control GmbH...

Отзывы: