background image

LDLF30x420-W5K7/UDC

Technical Data

5.2 Electrical Parameters

NOTICE

Verify that temperature, current and pulse time are kept inside specified

limits! Please refer to the diagram: 

"Pulse load "

.

There is no automatic limitation of the electrical parameters. The temperature

of the device is not monitored automatically.

Parameter

Min

Max

Continuous operation

LED current I

LED

2.5 A 

(1)

Forward voltage U

LED

 at I

LED Max

5.4 V

6.8 V

Power consumption P

tot

14.0 W 

(1)

Flash mode / Pulse mode

LED current I

LED

20.0 A 

(2)

Forward voltage U

LED

 at I

LED Max

7.0 V

8.4 V

Flash performance P

flash

145.0 W 

(2)

(1)

The maximum values refer to an ambient temperature of 25 °C and free

convection.

(2)

Verify that temperature, current and pulse time are kept inside specified

limits! Please refer to the diagram: 

"Pulse load "

.

18

999.995.459.10-en-2.2

© Vision & Control GmbH 2019

Содержание 1-13-887

Страница 1: ...ons for Use LDLF30x420 W5K7 UDC LED bar light diffuse illumination Luminous colour White 5700 K Instructions for Use LDLF30x420 W5K7 UDC LED bar light diffuse illumination Luminous colour White 5700 K...

Страница 2: ...this document on to third parties reproduce and communicate its contents in as far as this has not been expressly authorized Offenders will be liable for damages All rights are reserved with respect...

Страница 3: ...ct Identification Designation Description LDLF LED bar light diffuse illumination 30x420 Dimensions light emitting surface 30 mm x 420 mm W5K7 Colour temperature White 5700 K UDC User Defined Controll...

Страница 4: ...2 Notices on the device 15 5 Technical Data 16 5 1 General Parameters 16 5 2 Electrical Parameters 18 5 3 Photometric Parameters 20 5 4 Conditions for Operation Storage and Transport 21 5 5 Technical...

Страница 5: ...LDLF30x420 W5K7 UDC Table of Contents 8 1 Maintenance 31 8 2 Service 32 9 Disposal 33 10 EU Declaration of Conformity 34 Vision Control GmbH 2019 999 995 459 10 en 2 2 5...

Страница 6: ...LDLF30x420 W5K7 UDC 6 999 995 459 10 en 2 2 Vision Control GmbH 2019...

Страница 7: ...future reference 1 1 Intended Use The device is intended exclusively for use as a lighting element for industrial image processing in automation technology The device is not suitable for use in potent...

Страница 8: ...ons of use Using spare parts which are not original parts from the manufacturer Using incompatible accessory components Improper maintenance and repair works Unauthorised modifications to the device 1...

Страница 9: ...ual and rejects any warranty derived therefrom Within the bounds of the legal requirements the manufacturer shall only be responsible for the technical safety characteristics of the device if the main...

Страница 10: ...es of the danger These measures must be taken DANGER Indicates an imminent danger with high risk resulting in severe injuries or death if not avoided WARNING Indicates a hazardous situation with mediu...

Страница 11: ...ice and the connected technical equipment Hazards going beyond the general safety instructions are referred to separately at the relevant points in this manual CAUTION Risk of injury due to electric s...

Страница 12: ...Cable with M8 socket 4 pin straight 2 m 1 11 612 Cable with M8 socket 4 pin straight 3 m 1 11 613 Cable with M8 socket 4 pin straight 5 m Connection cable with 4 pin M8 socket and open cable end with...

Страница 13: ...r cable M8 4 pin 0 15 m 1 30 208 Adapter cable M8 4 pin 1 m 1 30 211 Adapter cable M8 4 pin 2 m Adapter cable with 4 pin M8 socket and 4 pin PTSM plug 4 x 0 5 mm PUR For connecting vicolux smart light...

Страница 14: ...ice Views 2 3 4 5 1 Image 1 Device view 1 Light emitting surface 2 3 x M3 mounting hole depth 10 5 mm on both sides 3 6 x M3 mounting hole depth 4 5 mm on both sides 4 Casing 5 Connection cable with 4...

Страница 15: ...ces on the device Following instructions are provided on the device Type plate Type XXXXXXXXXXX No XXXXXXXX 1 3 2 Image 2 Type plate 1 Device designation 2 Manufacturer information 3 Serial number Vis...

Страница 16: ...nodised Optical material PMMA Housing dimensions 35 mm x 442 mm x 22 mm without connector Dimensions light emitting surface 30 mm x 420 mm Weight 450 g Degree of protection IP IP 50 Safety class Class...

Страница 17: ...ending radius cable fixed at least 5 x cable diameter Bending radius cable moved at least 10 x cable diameter Bending cycles at least 4 million Robot suitable no Connector Parameter Characteristic Con...

Страница 18: ...eter Min Max Continuous operation LED current ILED 2 5 A 1 Forward voltage ULED at ILED Max 5 4 V 6 8 V Power consumption Ptot 14 0 W 1 Flash mode Pulse mode LED current ILED 20 0 A 2 Forward voltage...

Страница 19: ...le Power on time Power off time Image 3 Pulse load ADVICE To take advantages of the vicolux smart light technology enter the following Light Code in the user interface of your smart light controller a...

Страница 20: ...us 1 y 0 34 Continuous operation Radiance 60 W m sr Flash mode Pulse mode Radiance 285 W m sr 1 The values stated are maintained as from an LED current of 0 3 A Spectral Emission Relative spectral emi...

Страница 21: ...original packaging For accessories connected devices and components observe the specific information in the associated instructions for use Ambient Conditions Operation Storage Transport Temperature 0...

Страница 22: ...5 30 157 5 30 18 5 12 x M3 depth 5 5 20 7 5 on both sides 18 5 30 157 5 30 157 5 30 18 5 A 22 3 6 x M3 depth 4 5 A 150 15 5 3 x M3 depth 10 5 25 22 3 14 5 13 5 light emitting surface 19 420 442 30 31...

Страница 23: ...together with the device out of the carton 2 Fold out the tucked in sides on the bottom of the cardboard Loosening the film and forming an insertion pocket 3 Remove the device out of the insertion poc...

Страница 24: ...de energised state To mount the device tapped holes are located at the sides 3 1 2 1 12 x M3 tapped hole at the bottom Maximum screw in depth 5 5 mm 2 6 x M3 tapped hole at both long sides Maximum scr...

Страница 25: ...light lighting controller is not hot plug capable Connect or disconnect lights during operation may destroy the lights Connect or disconnect lights only if the lighting controller is in the off and d...

Страница 26: ...assignment 1 3 2 4 Image 6 M8 male plug 4 pin Connection diagram 3 BU 4 BK 1 BN WH 2 ILED ILED NC NC Pin Core colour Signal Description 1 BN brown ILED LED anode positive current input 2 WH white NC D...

Страница 27: ...light lighting controllers When using a vicolux smart light lighting controller the light is configured via the user interface DLC Server Control Center Refer to the Instructions of Use DLC Server Co...

Страница 28: ...are flashing lights or stroboscopes CAUTION Impairment of eye sight due to dazzling Do not look during operation directly in LED lighting or whose rays Wear protective goggles In the event of dazzling...

Страница 29: ...olux smart light lighting controller NOTICE Damage caused by incorrect connecting and disconnecting The vicolux smart light lighting controller is not hot plug capable Connect or disconnect lights dur...

Страница 30: ...r continuous operation apply a constant current ILED to the lighting Flash operation For pulse or flash operation apply current pulses ILED to the lighting Observe the specified parameters see Electri...

Страница 31: ...tside with a damp cloth Remove excessive dirt with an approved anodised aluminium cleaner Refer to the instructions of the cleaner The connectors must be clean and dry before the device is connected a...

Страница 32: ...glad to be of service Monday to Thursday 8 00 to 17 00 and Friday 8 00 to 15 00 Vision Control GmbH Mittelbergstra e 16 98527 Suhl Germany Phone 49 0 3681 7974 0 www vision control com Defective devic...

Страница 33: ...separately and sent to environmentally compatible recycling Disposal including that of individual components must also always be in a way that does not harm the environment which means it must be done...

Страница 34: ...rial environments DIN EN 61000 6 4 2011 09 Electromagnetic compatibility EMC Emission standard for industrial environments DIN EN 61000 4 2 2009 12 Electromagnetic compatibility EMC Testing and measur...

Страница 35: ...LDLF30x420 W5K7 UDC Vision Control GmbH 2019 999 995 459 10 en 2 2 35...

Страница 36: ...Vision Control GmbH Mittelbergstra e 16 98527 Suhl Germany Telephone 49 0 3681 7974 0 Telefax 49 0 3681 7974 33 Vision Control GmbH...

Отзывы: