Dosing system eco-CONTROL EC200 DUO
Operating and maintenance instructions
Version 1.4
Copyright ©
5.10.4 Dosing quantity
General on determining the dosing amount.
Notice:
If a value that differs from 100% is set in the
Calibration manual
menu
), this affects the results of the dosing.
The smallest dosing quantities can be determined most easily via the weight. We
recommend setting the material density first.
Dose your required quantity with the
Start / stop program
and weigh it. Now input in the
quantity program
the quantity in
g
.
Setting the dosing amount as a value
1. Press the
Quantity program
shortcut key, display 3
appears.
2. Ensure that the required quantity unit* has been selected
in the
Quantity
display area.
3. Set and confirm the dosing amount.
Displ
ay 3
5.10.5 Dosing time
1. Press the
Time program
shortcut key, display 10
appears.
2. Set, confirm and save the dosing time.
The set value remains active until the next change or until
the Dosing systems is switched off. Alternatively, a value of
its own for the flow rate can be assigned to each dosing
program (See 5.14, Changing a dosing program, page 29).
Displ
ay 10
5.10.6 Flow rate
The flow rate in quantity/min can be set in each dosing program. The
maximum flow rate that can be set is
6 ml/min, per dispenser (A and B). If a mix ratio of 1:1 is set, 12 ml/min is
conveyed.
• Selecting, changing and saving the displayed value.
Displa
y 34
The bar chart shows in what range (%) the flow rate is.
The set value remains active until the next change or until the Dosing systems is
switched off. Alternatively, a value of its own for the flow rate can be assigned to each
dosing program (See 5.14, Changing a dosing program, page 29).
Time program
Esc
Time
0%
100%
ml/min
01.00
03.000
00.000
ml
sec
Suckback
Flow rate
Flow rate
0%
100%
ml/min
03.000
Содержание PreeFlow eco-CONTROL EC200 DUO
Страница 2: ...Item number 20202 print 21 2 12 ...
Страница 39: ...Dosing system eco CONTROL EC200 DUO Operating and maintenance instructions Copyright Version 1 4 39 43 ...
Страница 40: ...Dosing system eco CONTROL EC200 DUO Operating and maintenance instructions 40 43 Version 1 4 Copyright ...
Страница 41: ...Dosing system eco CONTROL EC200 DUO Operating and maintenance instructions Copyright Version 1 4 41 43 ...
Страница 44: ......