5.14
Changing a dosing program
Only possible if using a memory card. If there is no memory card, then only program 00
(volatile memory) is available.
• Press the
PRG
key,
system selection menu
,
display 2 appears.
• Select
Administration
, display 25 appears.
D
is
pl
ay
2
• Activate
Select program
, display 26 appears.
Program 00 (volatile memory) or the last program that was
used is shown.
D
is
pl
ay
2
5
• Select and confirm the desired program number, all
program parameters (pages 1 and 2) can be changed.
D
is
pl
ay
2
6
Note
: The value in the
Pause
function defines the amount of
time between stopping the dosing and starting the sucking
back.
The pressure unit
Bar
can be changed over to
psi
.
D
is
pl
ay
2
6.
1
Start/stop
Time program
Calibration auto
Calibration manuel
Teach in function
Administration
Quantity program
10 47h
Fr 18.03.11
Service
Esc OK
Change program
Tolerance of pressure
Password protection
Analog input
Adjust time
Select program
10 47h
Fr 18.03.11
Esc
Program no.
00 / 2
Type
Desired pr.
Density
User no.
. . . . . . . . . . . . . . . . . .
Info
0.000
. . . . . . . . . .
1.0 Bar
Actual pr.
Quantity program
0.0 Bar
g/cm³