Page 20
2
Technical Data
Mains voltage ......................................................................... 230 V
Frequency ............................................................................... 50 Hz; 60 Hz
Power consumption ............................................................... 3.000 VA, 70 % ED
Output current (nominal current) .......................................... 80 A
Welding voltage ...................................................................... 8
–
48 V
Ambient temperature ............................................................ - 10°C to + 60°C*
Area of application VIWEL+ 400 .............................................
VIWEL+ 1200 ............................................
Fittings until 400 mm
Fittings until 1200 mm
Protection class ...................................................................... I
Protection type ....................................................................... IP 54
Transmission interface ........................................................... USB v 2.0
Storage capacity ..................................................................... 2.000 Welding logs
Overflow memory .................................................................. 47 Welding logs
Dimensions (L x W x H) ........................................................... about 500 x 250 x 320 mm
Weight including welder cable
(basic unit, without accessories)
........ about 21,5 kg
Contacts .................................................................................. 4 mm and 4.7 mm according to IEC 60529
* Cooling times vary with the ambient temperature. Direct sunlight should be avoided.
2.1
Measurement tolerances
Temperature ........................................................................... ± 5 %
Voltage .................................................................................... ± 2 %
Current .................................................................................... ± 2 %
Resistance ............................................................................... ± 5 %
3
Active Cooling System (ACS) and Heat Control (HC)
The device is fitted with a ventilator. This starts up as soon as the device is switched on at the main
switch. The fan assists in better removing the heat which arises in the device during welding. We
recommend therefore that the device is also switched off between two welding sessions in order to
optimize cooling of the device.
The device is fitted with a heat control function (HC). Before every welding session the device decides
whether the next welding session can be reliably performed to the end. Factors such as the current device
temperature, the ambient temperature and the welding data of the fittings play a role. If the current
device temperature is too high, the expected waiting time is displayed on the display. The ventilator
reduces this waiting time significantly.
4
Storage / transport
The device power connecting cable and the welding cable should be protected from sharp edges.
The welding device should not be subjected to strong mechanical loads.
The device should be stored at temperatures ranging from - 30 to + 70°C.