Maintenance
5
2.2 Cleaning and Replacing Quartz Sleeve
Note:
Minerals in the water slowly form a coating on the quartz sleeve. This coating must be removed because it reduces
the amount of UV light reaching the water, thereby reducing disinfection performance. If the sleeve can not be cleaned, it
must be replaced.
Prerequisites:
•
Disconnect the main power source and allow the system to cool for 10 minutes.
•
Shut off water supply and drain all lines.
•
Depressurize the unit. Place a small pail near the openings to catch any spills.
•
Remove the UV lamp. Refer to
Procedure:
Notes:
1) After replacing the UV lamp or quartz sleeve perform the disinfection procedure; refer to Owner’s Manual.
2) If the system is put on a temporary by-pass or if it becomes contaminated after the disinfection system, it is
necessary to shock the system with household bleach for a full 20 minutes before resuming the use of water.
1
•
Remove drain port plug from
chamber and drain the water.
Replace drain port plug once
chamber is drained.
22
1
2
3
4
•
Remove both retaining nuts,
spring and O-ring.
•
Carefully, remove the quartz
sleeve and second O-ring
from the other end.
3
Mild
Acid
•
Clean the quartz sleeve with a
cloth soaked in CLR, vinegar
or some other mild acid and
then rinse with water.
Note:
If sleeve cannot be
cleaned completely or it is
scratched or cracked, then
replace the sleeve.
4
4
3
2
1
•
Reinstall the quartz sleeve
with lubricated O-rings,
followed by spring and
retaining nut.
Note:
Use the supplied O-
rings.
•
When service is complete,
assemble the prerequisites in
the reverse order of
disassembly.