Chapter 5 - Configuring Northbound Switches for Fibre Channel and iSCSI Operations
88
7700 Flash Storage Platform Installation Guide 7.6.3.x
530-0267-00 Rev 02
Adding an iSCSI Target under an Existing iSCSI Client
If you want to add an iSCSI target in which its initiator resides in an existing iSCSI client and the IP
addresses for the target (typically, these are 10 GbE ports on the Memory Gateways) are known,
and the access settings are Read/Write Non-Exclusive, issue the command as shown:
To verify the name of the target you just created and its related information, issue the following
command:
To successfully ensure you connect to the initiator, use the
iscsiadm
command to check on the
client side that the name of the target node discovered by the initiator is the same as the one you
just created.
To perform this check, issue the following command:
Note:
If for any reason the name of the target displayed on the client side is not the same, you
need to issue the
iscsiadm
command to delete the old target node and re-discover the latest
target node created on the 7700 FSP Controller.
[root@san-array3003-mgb san-array3003-mgb]# isscli createiscsitarget -
c lab-ib1-cn6 -I 192.168.10.106,192.168.20.106 -a N
New ISCSI Target ID: 15
Command: createiscsitarget executed successfully.
[root@san-array3003-mgb san-array3003-mgb]# isscli getiscsitargetinfo -
r 15
ISCSI Targets: 1
Target Name Target ID IP Address Lun Access Mode Target Type Always
Redirect Redirect IP Address
----------------------------------------------------------------------
iqn.2004-02.com.vmem-concerto.lab-fil3003-mgb.lab-ib1-cn6-15 15
192.168.10.106 192.168.20.106 0 Read/Write Non-Exclusive iSCSI false
(null)
Command: getiscsitargetinfo executed successfully.
[root@lab-ib1-cn6 ~]# iscsiadm -m node
192.168.20.106:3260,0 iqn.2004-02.com.vmem-concerto.san-array3003-
mgb.lab-ib1-cn6-15
192.168.10.106:3260,0 iqn.2004-02.com.vmem-concerto.san-array3003-
mgb.lab-ib1-cn6-15
Содержание 7700
Страница 12: ...Preface 6 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 122: ...Appendix A System Reference 116 7700 Series Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 144: ...Appendix C Configuring Replication 138 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 180: ...Appendix G Managing HA Using CLI Commands 174 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 195: ...Korea RFI Statement 530 0267 00 Rev 02 7700 Flash Storage Platform Installation Guide 7 6 3 x 189 Korea RFI Statement ...
Страница 202: ...Appendix H Compliance Information 196 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 208: ...202 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...