Appendix D - Configuring Brocade 6510 Fibre Channel Switches
140
7700 Flash Storage Platform Installation Guide 7.6.3.x
530-0267-00 Rev 02
4.
Start the Console session, which prompts you to change the default settings and set new FC
switch passwords for "
root"
, "
admin"
, "
factory"
, and "
user"
.
Any new passwords that you set must observe existing customer-based corporate or network
password naming conventions, and make sure that all new passwords are recorded. In
addition, to inspect and change account passwords, you can use the following:
•
To change the current login: log in using "
admin
" and "
passwd
".
•
To inspect the current login accounts: log in and issue
userconfig -show
<username>
or
userconfig -show -a
.
•
To change another login password: log in using "
admin
" and "
passwd <username>
".
5.
Type "
ipaddrset"
to set new IP addresses for the FC switch Management, subnet mask,
and default gateway to uniquely identify them on the network.
6.
Connect the FC switch Management network RJ-45 port to the management network.
7.
Confirm that this connection is valid and functional by using the "
ping
" command with the
gateway IP address.
8.
Type "
exit"
and logout.
9.
Continue FC switch management using SSH and the Management IP address you just
assigned.
10.
Repeat these steps on the second Brocade 6510 FC switch in your 7700 FSP storage cluster
system.
Configuring the Brocade 6510 FC Switch
To set the FC switch hostname and network services for each Brocade 6510, perform the following:
Note:
To get instructions for any Brocade CLI command, prepend the command with "
help
".
1.
Start a terminal session (using PuTTY or a similar SSH program) to connect to the
Management IP address.
2.
Change the default FC switch name by issuing the
switchname "<new-switchname>
" CLI
command, as shown:
switchname:user> switchname "FC7700-switch-a"
Committing configuration...
Done.
Switch name has been changed. Please re-login into the switch for the
change to be applied.
switchname:root> logout
FC7700-switch-a:root>
Содержание 7700
Страница 12: ...Preface 6 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 122: ...Appendix A System Reference 116 7700 Series Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 144: ...Appendix C Configuring Replication 138 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 180: ...Appendix G Managing HA Using CLI Commands 174 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 195: ...Korea RFI Statement 530 0267 00 Rev 02 7700 Flash Storage Platform Installation Guide 7 6 3 x 189 Korea RFI Statement ...
Страница 202: ...Appendix H Compliance Information 196 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 208: ...202 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...