Troubleshooting Memory Gateways
530-0267-00 Rev 02
7700 Series Flash Storage Platform Installation Guide 7.6.3.x
115
Error Messages When Logging in to Memory
Gateways
Complete the steps described in this section if any of the following warning messages display:
•
“
WARNING: POSSIBLE DNS SPOOFING DETECTED!
”
or
•
“
WARNING: REMOTE HOST IDENTIFICATION HAS CHANGED!
”
The following steps allow you to log in to the Memory Gateways from either ACM:
1.
Log in to the ACM Master.
2.
Type the following at the command prompt to access the CLI’s configuration mode:
3.
Type the following commands:
violin-acma [violin: master] >
enable
violin-acma [violin: master] #
configure terminal
(config) #
ssh client user admin known-host mg-a remove
(config) #
ssh client user admin known-host mg-b remove
(config) #
ssh client user admin known-host 169.254.1.101 remove
(config) #
ssh client user admin known-host 169.254.1.102 remove
Содержание 7700
Страница 12: ...Preface 6 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 122: ...Appendix A System Reference 116 7700 Series Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 144: ...Appendix C Configuring Replication 138 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 180: ...Appendix G Managing HA Using CLI Commands 174 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 195: ...Korea RFI Statement 530 0267 00 Rev 02 7700 Flash Storage Platform Installation Guide 7 6 3 x 189 Korea RFI Statement ...
Страница 202: ...Appendix H Compliance Information 196 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...
Страница 208: ...202 7700 Flash Storage Platform Installation Guide 7 6 3 x 530 0267 00 Rev 02 ...