User Manual
Espace Walk-in Cellar
6
Installing your cellar (cont'd)
Preparation for installation
CRITICAL WARNINGS:
• LOCATION FLOOR LOAD:
This walk in cellar and
its contents are EXTREMELY heavy. It is vital that the
floor where it will be located is level and strong enough
to handle the load. For example, the Espace1000
base unit weighs 310kg installed, but loading in 1000
standard wine bottles adds a further static load of
approximately 1500kg. Each 500 bottle extension kit
weighs a further 150kg plus the extra wine weight
(~1.5kg per average bottle). if you are not certain of
the floor load capacity at the planned location We
recommend consulting an architect or structural
engineer to assess its strength before receiving
delivery or commencing assembly of your cellar.
• DELIVERY: Espace cellars are supplied flat-packed in
solid wooden crates that weigh up to 400kg in total
(espace1000-kit) or a minimum of 150kg (espace1000-
ext). Due to the crates’ weight and size, careful
consideration should be given to site accessibility, as
well as the safe lifting capacity of any equipment being
used to transport and manoeuvre the crates.
• ASSEMBLY: The cellar should be assembled in the
same room or space as its final permanent location,
because once constructed it will be too wide to move
through a standard door opening.
IMPORTANT CONSIDERATIONS:
• Space for assembly: Allow ample room for assembly
of the cellar’s walls. The gap should be big enough to
allow the walls to be screwed together and for you to
move around it easily during assembly (see below).
TOP VIEW
500 min.
500 min.
Door
Conditioner
500 min.
NOTE: Once assembled, you can install the cellar into
a space with less or no space at the sides and back, as
long as you are able to move the cellar into that space
once assembled (will not fit through a standard doorway).
See warning below regarding roof access.
Also allow enough clearance from the ceiling to lift and
fit the roof of the cellar during assembly (see below).
WARNING:
Once assembled
and installed,
you should
ideally ensure
there is still
enough room
to allow access
to the electrical
power lead outlet
on the roof
(for more info
see 'Power' on
page 7).
SIDE VIEW
Door
Conditioner
500 min.
2500 min.