Vinotemp WINE-MATE WM-2500SSOWC Скачать руководство пользователя страница 1

Split  Water-Cooled  Through-Ceiling  Cooling  System 

Operation Care Installation Manual 

WM-2500SSOWC 
WM-4500SSOWC 

www.vinotemp.com 

Read and save these instructions 

Vinotemp International Corp 
732 South Racetrack Road, Henderson, NV 89015 
Tel: (800) 777-VINO Fax: (310) 886-3310 Email: [email protected] 

Содержание WINE-MATE WM-2500SSOWC

Страница 1: ...stem Operation Care Installation Manual WM 2500SSOWC WM 4500SSOWC www vinotemp com Read and save these instructions Vinotemp International Corp 732 South Racetrack Road Henderson NV 89015 Tel 800 777...

Страница 2: ...cle installed by a qualified electrician DO NOT UNDER ANY CIRCUMSTANCES REMOVE THE POWER CORD GROUNDING PRONG A separate adequately fused and grounded circuit should be available for this appliance Do...

Страница 3: ...2 Table of Contents Cellar Construction Guide 3 Features Specifications 4 Temperature Humidity 6 Care Guide 10 User Troubleshooting 11 Installer s Instructions 14 Electrical Wirings 25 Warranty 26...

Страница 4: ...temperature surrounding the cellar shall not exceed the temperature of the cellar by morethan 25 F No cellar walls shall receive direct sun or strong wind Lighting shall be of low wattage with a time...

Страница 5: ...units can be installed through the ceiling outside a wine cabinet or room The evaporator units are designed to maximize storage space SSOWC cooling systems consist of a remote condensing unit and an e...

Страница 6: ...sing unit ambient temperature with R13 interior and R19 exterior insulations Higher ambient temperatures or lower insulations will cause reducing capacity and the cellar temperature may not be maintai...

Страница 7: ...ock the keypad SET To enter in the programming mode SET To return to the temperature display 2 Lock and unlock the keys To lock the keys press up down keys until POF is displayed to unlock the keys pr...

Страница 8: ...nstrument 2 Temperature Setting Set the temperature at 55 F for the optimum aging of wine On initial start up the time required to reach the desired temperature will vary depending on the quantity of...

Страница 9: ...e regulation differential 4 AC anti short cycle delay min 10 hidden Con compress on with probe faulty min 15 CoF compress off with probe faulty min 30 CF temperature unit F C F Fahrenheit rES display...

Страница 10: ...ative humidity Use a separate hygrometer to monitor the humidity 10 How to set alarm call 1 Speech notice will be sent to your phones when the cellar temperature is ALU higher or ALL lower than the se...

Страница 11: ...aning To clear any sediment that may accumulate the water regulating valve may be manually flushed Insert screwdrivers under both sides of the valve spring guide and lift upwards to flush 2 Condensate...

Страница 12: ...the cooling unit turns on at 59 F of air temperature It may be higher than 59 F if it is in anti short cycle or defrost and turns off at 55 F of air temperature The average airtemperature is 57 F and...

Страница 13: ...otector compressor c Call service 11 Temperature low a Low temperature setting b Low ambient temperature c Air probe fault d Temperature controller fault a Raise the setting b Move to another location...

Страница 14: ...ion b Use dehumidifier c Increase air flow or raise temperature setting 17 Circuit tripping a Incorrect fuse or breaker b Incorrect wirings c Failed components a Check for proper fuse or breaker b Che...

Страница 15: ...nician has properly installed the system Proper installation is critical Vinotemp can only warrant the quality of the components The installation and proper operation of the system must be warranted b...

Страница 16: ...for electrical wiring and refrigeration piping Model No Evap Unit L x W x H L1 x W1 Cond Unit L x W x H Electrical Rating Evap Unit Cond Unit Min Circuit Ampacity A Weight lb Evap Unit Cond Unit WM 2...

Страница 17: ...16 Fig 4 WM 25 45SFCO Evaporator Unit Fig 5 WM 250 450SCUR WC Condensing Unit...

Страница 18: ...W1 2 Air supply shall be unobstructed minimum 12 air return shall be unobstructed minimum 6 3 There is a gravity drain system so the unit shall be installed level or with a slight slope downward the d...

Страница 19: ...set exceeds 75 ft long use both inverted U trap and suction accumulator to prevent liquid from flooding back to the compressor 3 If the condensing unit is located below the evaporator unit use invert...

Страница 20: ...e operation liquid or suction line connection is closed Middle Position Installation operation all ports are open NOTE The recommended initial charges are used for reference only always use the superh...

Страница 21: ...ing the Installation 1 Set the water regulating valve opening set point at refrigerant pressure of 120 PSIG Turn counterclockwise to raise the operating set point Fig 10 Water Regulating Valve 2 Check...

Страница 22: ...h the water outlet temperature 120 190 psig at the water outlet temperature 95 120 F 6 The evaporator s constant pressure expansion valve is set around 30 35 psig 35 40 F at factory This pressure sett...

Страница 23: ...adpressure Low superheat and high subcooling 4 High to normal suction pressure and highhead pressure Low subcooling 5 High suction pressure and high headpressure Low superheat and low subcooling 6 Hig...

Страница 24: ...nd high head pressure Normal to high superheat and high subcooling restricted 9 Suction line restricted 10 Air restricted at evaporator evaporator iced 11 Evaporator restricted 12 Expansion valve rest...

Страница 25: ...e field wirings Use minimum 14 gauge wires for power lines If equipped with low ambient condition kit use low ambient temperature wiring diagrams A safety switch is always recommended for the condensi...

Страница 26: ...lied including any of fitness for a particular purpose In no event shall VINOTEMP be responsible for any consequential damages what is so ever Any modification of VINOTEMP products shall void this war...

Страница 27: ...BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE While great effort has been made to provide accurate guidelines VINOTEMP cannot warrant its units to proper...