background image

 

www.winemate.com

www.winemate.com

 

 

 

Wall Split Cooling System 

 

Installation, Operation & Care Manual

 

 

WM-1520SSW WM-2520SSW

 

 

 

www.vinotemp.com

www.vinotemp.com

 

 

Read and save these instructions

Read and save these instructions

 

 

Содержание Wine-Mate WM-1520SSW

Страница 1: ...mate com www winemate com Wall Split Cooling System Installation Operation Care Manual WM 1520SSW WM 2520SSW www vinotemp com www vinotemp com Read and save these instructions Read and save these inst...

Страница 2: ...1 Important Safety Information WARNING Do not use a ground fault interrupter GFI A dedicated 10 AMP circuit is required...

Страница 3: ...le of Contents Cellar Construction 3 Features Specifications 4 Temperature Humidity 6 Care Guide 10 User Troubleshooting 11 Installer s Instructions 15 Electrical Wirings 24 Customer Support 26 Warran...

Страница 4: ...rature surrounding the enclosure shall not exceed the temperature of the cellar by more than 25 F No cellar wall shall receive direct sun or strong wind Lighting shall be of low wattage with a timer t...

Страница 5: ...g units can be located away from the wine cellars 50 ft so that noise and compressor vibration are isolated SSW evaporator units can be installed inside a wine rack or between two wall studs making th...

Страница 6: ...it L xD xH Cond Unit L xD xH Btu h CFM Cellar Size cu ft Refrigerant Electrical Evap Unit Cond Unit Weight lb Evap Unit Cond Unit WM 1520SSW WM 152SFCW 16x5 5x36 WM 152SCU 18x14x12 1200 90 140 R134a 2...

Страница 7: ...the keypad SET To enter in the programming mode SET To return to the temperature display 2 Lock and unlock the keys To lock the keys press up down keys until POF is displayed to unlock the keys press...

Страница 8: ...at 55 F for the optimum aging of wine On initial start up the time required to reach the desired temperature will vary depending on the quantity of bottles temperature setting and surrounding tempera...

Страница 9: ...lty min 30 CF temperature unit F C F Fahrenheit rES display resolution in integer dLy temperature display delay min 1 ot probe calibration 0 LS minimum set point 50 US maximum set point 65 idF defrost...

Страница 10: ...Speech notice will be sent to your phones when the cellar temperature is ALU higher or ALL lower than the set point Set 2 In order to test the call function set parameters Ald 0 and dAO 0 After testi...

Страница 11: ...lean the condenser coil regularly Coil may need to be cleaned at least every 6 months Use a vacuum cleaner with an extended attachment to clean the coil when it is dusty or dirty 2 Condensate Removing...

Страница 12: ...mperature is mainly controlled by the average air temperature If the set point is 55 F with the differential 4F the cooling unit turns on at 59 F of air temperature It may be higher than 59 F if it is...

Страница 13: ...ide and leave minimum 1 foot clearance for the ambient air intake side c Check for excessive size d Check for installation location e Clean condenser f Check for fan and air short circulation 8 Conden...

Страница 14: ...ir flow restriction d Drain restricted or unit not level and water overflowing e Drip tray leak No overflow but leak a Check for air leak b Use drain line c Check supply air flow or air TD d Clean the...

Страница 15: ...14 high ambient temperatures or airflow restriction d Defective components d Call service for checking internal loose inadequate lubrication and incorrect wirings...

Страница 16: ...tate and local building and electrical codes The condensing unit and evaporator unit are connected by a liquid line and an insulated suction line that are supplied by the installer These lines must be...

Страница 17: ...16 CAUTION Liquid and suction line locations may differ from what are shown here please check on the units for proper installation Fig 3 WM 152 252SFCW Evaporator Unit...

Страница 18: ...turn area but it shall not be located in the air supply area or other areas where air is not circulated 2 Air probe can be pulled out of the temperature controller around 5 ft if additional wires are...

Страница 19: ...condensing unit has been powered for minimum 12 hours 1 Place the condensing units WM 152 252SCU in a properly ventilated location If it is not heat exhausted by the condensing unit will build up and...

Страница 20: ...ION FRONT POSITION MIDDLE POSITION Fig 8 Base Valve Operation 5 Checking Pressure Control Settings 1 Use of the encapsulated pressure control if applicable Fixed suction pressure setting Cut in 32 psi...

Страница 21: ...zes of evaporator unit are not necessary the same as the listed refrigeration line sizes If the condensing unit is installed above the evaporator unit use the suction line one listed size smaller Expa...

Страница 22: ...sed for reference only If the unit is equipped with a low ambient condition kit and installed in the summer charge 15 more refrigerant If the low ambient condition kit is used turn off the compressor...

Страница 23: ...tor shall be 8 10 F at 55 F wine cellar temperature 6 Again you must verify if the superheat at the evaporator unit is around 9 18 F at 55 F high wine cellar temperatures 7 If the superheat is high ch...

Страница 24: ...e High superheat and normal subcooling 13 Low suction pressure and high head pressure High superheat and high subcooling 14 Low suction pressure and high head pressure High superheat and high subcooli...

Страница 25: ...are the field wirings Use minimum 14 gauge wires for power lines If equipped with low ambient condition kit use low ambient temperature wiring diagrams A safety switch is always recommended for the co...

Страница 26: ...25 Fig 14 Low Ambient Temperature WM 1520 2520SSW LA Electrical Wiring Diagram...

Страница 27: ...6 Customer Support If you need further assistance please contact us at Vinotemp International 17631 South Susana Road Rancho Dominguez CA 90221 Tel 310 886 3332 Fax 310 886 3310 Email info vinotemp co...

Страница 28: ...and is in lieu of all other warranties express or implied including any of fitness for a particular purpose In no event shall VINOTEMP be responsible for any consequential damages what is so ever Any...

Страница 29: ...NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE While great effort has been made to provide accurate guidelines VINOTEMP cannot warrant its units to properly...