READ AND SAVE THESE INSTRUCTIONS 

 

Содержание WINE-MATE VINO-2500SSR

Страница 1: ...it System Installation Operation Care Manual VINO 2500SSR VINO 4500SSR V Vi in no ot te em mp p I In nt te er rn na at ti io on na al l C Co or rp p www winemate com www winemate com READ AND SAVE THESE INSTRUCTIONS ...

Страница 2: ...TABLE OF CONTENTS Important Safety Information 2 Feature Description 3 Installer s Instruction 5 Temperature Control 9 Care Guide 14 User Troubleshooting 15 Customer Support 18 Warranty 19 1 ...

Страница 3: ...Important Safety Information DO NOT USE A GROUND FAULT INTERRUPTER GFI A DEDICATED 20 AMP CIRCUIT IS HIGHLY RECOMMENDED 2 ...

Страница 4: ...et which will bring you quiet operation SSR units are designed for installation inside a wine rack or between two ceiling joists making them an ideal choice for small and medium wine rooms The dimensions and capacity are specified as follows MODEL EVAP UNIT L xH xD COND UNIT L xH xD Btu h 55 F 90 F CFM WINE CAPACITY REFRIGERANT ELECTRICAL EVAP UNIT COND UNIT WEIGHT lb EVAP UNIT COND UNIT VINO 2500...

Страница 5: ...Fig 1 1 WM25 45SFCR Evaporator Unit Fig 1 2 WM25 45SCU Condensing Unit 4 ...

Страница 6: ...d for the distance between the two units After the units and the lines are installed the system must be pressure tested If no leaks are found evacuate and charge system with R134A Refrigerant amount will vary depending on the length of line set 1 Condensing Unit Place the condensing unit in a properly ventilated location If it is not heat exhausted by the condensing unit will build up and the cool...

Страница 7: ...OD R134a 18 OZ VINO 4500SSR 1 4 OD 1 2 OD 50 FT 1 2 OD R134a 24 OZ 4 Pressure Gauge Readings Low side pressure 33 psig High side pressure 130 psig at 75 F ambient temperature and 150 psig at 90 F ambient temperature Complaint Possible Causes a High at low side and low at high side b High at low side and normal at high side c High at low side and high at high side d Normal at low side and high at h...

Страница 8: ...5 Valve Operation SPINDLE FRONT POSITION SPINDLE BACK POSITION SPINDLE MIDDLE POSITION Fig 2 1 Valve Operation 6 Electrical Wiring 7 Fig 2 2 VINO2500 4500SSR Electrical Wiring Diagram 952884 ...

Страница 9: ...rect or loose wirings c Failed components d Liquid refrigerant in the compressor e Low pressure switch shutting down the system a Check for proper voltage b Check all wirings and connections c Check start relay start capacitor overload protector compressor d Call service for OEM information e Check for system restriction or low refrigerant 8 ...

Страница 10: ...t up the time required to reach the desired temperature will vary depending on the quantity of bottles temperature setting and surrounding temperature Allow 24 hours to stabilize the temperature for each new temperature setting operation 2 Use of the 952884 controller Fig 3 1 Digital controller 9 Dip Switch Setting ...

Страница 11: ...ds It is possible to choose between an electric defrost the compressor is deactivated and the defrost relay is activated and a hot gas defrost both the compressor and the defrost relay are activated The defrost termination can take place by time from 1 to 60 min or by temperature from 0 to 86 F if the defrost sensor is utilized for the correct programming If the defrost sensor is disconnected inte...

Страница 12: ...l Controller 1 Display During normal operating conditions the display shows the value measured by the air regulation probe In case of active alarm the temperature flashes alternately to the code alarm 1 1 LED Functions 11 1 2 Front Panel Commands ...

Страница 13: ...matically stops as soon as the temperature returns to normal value Alarm CA with i1F PAL recovers only by switching off and on the instrument 3 Temperature Set Point 3 1 How to see the set point 1 Push and immediately release the SET key the display will show the Set point value 2 Push and immediately release the SET key or wait for 5 seconds to display the probe value again 3 2 How to change the ...

Страница 14: ...e C or F LED starts blinking 3 To change the Set value push the o or n arrows within 10s 4 To memorize the new set point value push the SET key again or wait 10s 4 Manual Defrost Push the DEF key for more than 2 seconds and a manual defrost will start 13 ...

Страница 15: ...eed to be cleaned at least every 6 months Unplug the system or disconnect power Use a vacuum cleaner with an extended attachment to clean the coil when it is dusty or dirty Plug cooling system or reconnect power 2 Moisture Removing Remove the extra condensate if it is accumulated in the wine cellar at high ambient temperature and humidity 14 ...

Страница 16: ... F of air temperature and turns off at 55 F of air temperature The average air temperature is 57 F and then the wine temperature is around 57 0 5 F The air is light enough to change so quickly that it maintains relatively constant average temperature that would prevent wine bottle temperature from varying 3 Temperature too high a Setting too high b Improper room insulation seal c Room too large d ...

Страница 17: ...harge of refrigerant h Discharge or suction pressure too high a Set 55 to 60 F b Check for voltage c Check thermistor by placing it in ice water and measuring resistance d Check compressor windings start relay and overload protector e Check for condenser fan f Clean condenser g Call service for removing refrigerant h Call service for OEM information 6 No cooling but unit running a Evaporator airfl...

Страница 18: ...atures or airflow restriction d Malfunctioning components a Add support to improve installation b Check fan blades bearings cabinet washers tubing contact and loose screws c Check for airflow blockage d Call service for checking Internal loose inadequate lubrication and incorrect wirings 17 ...

Страница 19: ...Customer Support If you still have problems please contact us at Vinotemp International 17631 South Susana Road Rancho Dominguez CA 90221 Tel 310 886 3332 Fax 310 886 3310 Email info vinotemp com 18 ...

Страница 20: ...s express or implied including any of fitness for a particular purpose In no event shall VINOTEMP be responsible for any consequential damages what is so ever Any modification of VINOTEMP products shall void this warranty Service under Warranty This service is provided to customers within the continental UNITED STATES only VINOTEMP cooling units are warranted to produce the stated number of BTU H ...

Страница 21: ...E OF THE UNIT LOSS OF TIME OR COMMERCIAL LOSS ANY OUTER DAMAGES WHETHER INCIDENTAL CONSEQUENTIAL OR OTHERWISE THIS WARRANTY IS EXCLUSIBE AND IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR INPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE While great effort has been made to provide accurate guidelines VINOTEMP cannot warrant its units to...