Turbine Industrial Intercoms
Mounting Manual
Contents of this Delivery
The unit comes with 5 blind plugs already mounted. The front frame is fastened with 2 socket-head cap M6
screws.
Important Notes before Mounting
Improper installation and operation of the unit will result in the invalidation of the warranty.
The enclosure/housing must not be opened when the unit is powered.
The installation and connection of units may only be carried out by qualified/approved personnel
General Mounting Considerations
When the unit is mounted directly onto a wall or mounting plate, it shall rest only on the fastening points provided for
this purpose. The surface must be even and flat.
The unit must be mounted on a surface to prevent access from the rear of the unit.
Do not use countersunk screws.
Due to the enclosure material, use as low a tightening torque as possible when mounting the unit to the surface
(1.5 Nm max.)
Washers are recommended.
Do not use more than 2.5 Nm torque when fastening the 12 screws into the front frame.
On Mounting Plate or Column - recommended screws:
M5 x 20 or 25 with Philips head DIN7985 or Torx.
Head diameter: 10 mm.
On Wall - recommended screws:
Panhead – DIN7981 for plug or wooden wall, etc.
Head diameter: 10.8 B5.5 x 38 or 45 mm.
This Manual
10 socket-head cap M6 screws
(+ 2 fastened to front frame)
1 Cable Gland M16 1P68
1 Cable Gland M20 1P68
TFIE-1 1008122010
TFIE-2 1008122020
TFIE-6 1008122060