Vingtor Stentofon TCIS-1 Скачать руководство пользователя страница 1

The information in this document pertains to the Turbine 

Compact IP Stations TCIS-1/TCIS-1-V, TCIS-2,  TCIS-3, 

TCIS-4, TCIS-5, TCIS-6, TKIS-1.

Turbine TCIS-1/TCIS-1-V Station Keys & Functions

Turbine TCIS-6 Station Keys & Functions

Loudspeaker

Cancel

Microphone

Manual Speech

Direction Control

Call Button

Loudspeaker

Cancel

Microphone

Call Button

Scroll Up

Scroll Down

PMOLED

Display

1  Station Connections

1.1  External Connectors

The following table is an overview of the main connectors 

involved when installing the Turbine IP Stations.

Ethernet/Power

10/100 Mbps Ethernet RJ-45 port for LAN (uplink) 

connection. Supports PoE (802.3af). Draws power from 

either spare line or signal line.

Secondary 

Power

24 VDC (16 – 48 V) secondary power is provided from an 

external adapter. 

Relays

There is one Double Throw relay contact with 60W 

switching power. COM, NO, NC contacts are provided. Max: 

250VAC/220VDC, 2A, 60W.

Input/Output

6 general purpose I/Os are available. Each I/O can be 

configured as either button input or LED driver. 

Audio Line Out

A balanced 600 ohm audio line out with induction loop signal

1.2  Power Supply

The Turbine Station supports Power over Ethernet (PoE, 

IEEE 802.3 a-f) where power can be drawn from either the 

spare line or signal line. 
If PoE is not available, the Turbine Station can be connected 

to a 24 VDC local power supply.

1.3  Network Connection

There is one RJ-45 port located on 

the Turbine station that is used as the 

PoE/LAN port.

PoE port

1.4  Input/Output Connections

There are 6 I/O connection options for the Turbine Station. 

These connections are used as relay contacts for door lock 

control and external I/O devices.

1

5

4

3

2

1

6

10

5

4

3

2

9

8

7

RJ-45

PoE

port

24 VDC for external secondary power 

if PoE is not used. Pin 1 is positive.

- 5.3V (LED driver)

- GND

- Input/Output 5

- COM relay

- NC relay

- NO relay

- Input/Output 1

- Input/Output 2

- Input/Output 3

- Input/Output 6

- 600 ohm balanced line out +
- 600 ohm balanced line out -

- Input/Output 4

E

th

er

ne

t C

on

ne

ct

io

Turbine Compact IP Stations

Getting Started for Pulse