TECHNICAL MANUAL

MASTER CLOCK SYSTEM

TECHNICAL & USER MANUAL

A100K10807

Содержание 3005050028

Страница 1: ...TECHNICAL MANUAL MASTER CLOCK SYSTEM TECHNICAL USER MANUAL A100K10807 ...

Страница 2: ...le connection diagram A100K10836 V1 3 16 06 2015 SEN Masterclock Protection changed to IP 22 page 8 V1 4 25 11 2015 SEN Updated cable connection diagram A100K10836 v1 5 12 05 2016 SEN Updated cable connection diagram A100K10836 v1 6 24 08 2016 SEN Updated A100K10836 changes on term block 6 V1 7 13 11 2018 HKL New manual versions 1717en19 1795en03 9539en14 V1 8 17 6 2019 HKL Power supply 50 60 Hz R...

Страница 3: ...ode Clock Document 1785en03 doc Date 2009 11 04 5 pages 3 Option Ethernet Marine Master Clock Document 1795en03 Date 2014 05 08 11 Pages 4 Technical Specification Marine Master Clock Document 9539en14 Date 2018 08 15 5 Pages 5 Cable Connection Cable Connection Diagram Document A100K10836 1 Page Cable Calculation Document A100K11451 1 Page Dimensions Drawing Document A100K10838 1 Page ...

Страница 4: ... doc Author PM User Manual Date 2017 12 22 Page 1 of 51 WESTERSTRAND URFABRIK AB P O Box 133 Tel 46 506 48000 Internet http www westerstrand se SE 545 23 TÖREBODA Fax 46 506 48051 E mail info westerstrand se User Manual Marine Master Clock ...

Страница 5: ...ions this page 9 2 Output configuration Setup page 10 9 3 Enter time of Slave Clocks page 12 9 OUTPUT CONFIGURATION SETUP 10 SET UTC WHEN IN OPERATION 11 SET LOCAL TIME WHEN IN OPERATION 11 SLAVE CLOCK 12 TIME ZONE ADJUSTMENT 13 ALARMS 14 Example 1 display alarms 14 Example 1 erase alarms 15 Alarm list 16 WEEK PROGRAM DATE PROGRAM 17 Concept description 17 Week Program example 1 New program 19 Wee...

Страница 6: ...e 2017 12 22 Page 3 of 51 WESTERSTRAND URFABRIK AB P O Box 133 Tel 46 506 48000 Internet http www westerstrand se SE 545 23 TÖREBODA Fax 46 506 48051 E mail info westerstrand se Default LT adjust 46 Display format 47 PROGRAMMING FORM 48 FAULT TRACING 49 ALARM OUTPUT 50 ...

Страница 7: ...output Output 1 2 and 3 Impulse system 1 1 minute 1 2 minute second Time Code TC Type of time LT UTC Impulse length Minute 0 1 9 9 sec Second 0 1 1 sec Output 4 Impulse system 2 wire 1 1 minute 1 2 minute second Time Code TC 3 wire for Forward Reverse movement 1 1 minute alt 1 2 minut Type of time LT UTC Impulse duration Minute 0 1 9 9 sec Second 0 1 1 sec Maximum load output 2A The output is equi...

Страница 8: ...ation sources can be connected when higher accuracy is needed For control and regulation of various energy consumers such as electrical striking plates buzzers for pause signalling etc the master Clock has a built in yearly programmer with two relay outputs The Master Clock is equipped with 10 buttons and a 2 x 16 character LCD To facilitate the change of time zone two of the buttons are dedicated...

Страница 9: ...t Cancel Leave programming mode Move right NO Decline YES Accept Enter programming mode ADV Advance Local Time REV Reverse Local Time Relay output control switches 1 Always ON 0 Always OFF A Automatic position ON OFF according to program Status monitoring LED s Alarm An alarm has occurred for instance short circuit on one of the output lines Power Power is ON Radio Indicating signal coming from an...

Страница 10: ...ll analogue slave clocks shows the same time for instance 12 00 4 Before connecting the slave clock lines check the wires for short circuit faulty connections etc 5 Connect the slave clock lines 6 Connect the signal line lines to relay contacts 7 NOTE For connection of signals etc mixed voltages must not be used Therefore choose either 230VAC or for example 24VAC for connection to the relays 8 Con...

Страница 11: ...ming Programming is self instructive and to simplify the dialogue Yes No questions are used Running mode When the Time Base module is in operation it shows date and time in the display This is called running mode in this documentation 1 Select function 2 Enter programming mode YES 3 Move sideways 4 Change scroll 5 Accept YES 6 Cancel Leave prog mode MON 26 SEP 2016 U10 11 35 L12 11 SET UTC MON 26 ...

Страница 12: ...ime correct requested language has to be entered Press NO until requested language occurs in the display e g English Accept with YES Set by using the arrows the right UTC Time format Year month date hour minute second Set the time a minute in advance Wait for the right time and synchronise using YES Set by using the arrows the right Local Time Time format Year month date hour minute second Set the...

Страница 13: ...cial function Setup If the default setup is used no configuration is needed Default setup Slave Clock output no 1 Impulse system 1 1 minute Type of time UTC Impulse length 2 sec Slave Clock output no 2 Impulse system Type of time Impulse length Slave Clock output no 3 Impulse system Type of time Impulse length Slave Clock output no 4 Impulse system 3 wire for Forward Reverse 1 1 minute Type of tim...

Страница 14: ... mode by pressing several times The master clock is now back in running mode Set Local Time when in operation Remark To do normal Time Zone adjustments use the buttons ADV and REV Select function using Enter the programming mode with YES Set by using the arrows the right Local Time Time format Year month date hour minute second Set the time a minute in advance Wait for the right time and synchroni...

Страница 15: ... YES if not set the time shown by the slave clocks Turn ON impulse output 1 by using Accept with YES Leave programming mode by pressing several times The master clock is now back in running mode NOTE If a slave clock runs out by a minute its cabling must be pole changed and the slave clock to be corrected manually NOTE If the time of the slave clocks is ahead of correct present time the Master Clo...

Страница 16: ...s When the correction is finished the display is automatically returned to running mode To reverse the Local Time slave clocks to a new time zone press button REV Example Press button REV Use the default value or change by pressing REV Accept with YES The Local Time slave clocks will now be adjusted as below 1 Min forward clock s stop 60 min 0 5 Min F B clock s Reverse 60 Min TC Clock s 11 hours f...

Страница 17: ...is used to display and erase the different alarms in the master clock To show the alarms To erase the alarms Example 1 display alarms Select function using Accept with YES Press NO until the wished function is shown Accept with YES The alarm is displayed Press to see next alarm Return to running mode press ALARMS DISPLAY ALARMS ERASE MON 26 SEP 2016 U10 11 35 L12 11 ALARMS 09AUG 15 52 NO RADIO 30 ...

Страница 18: ...DA Fax 46 506 48051 E mail info westerstrand se Example 1 erase alarms Select function using Accept with YES Press NO until the wished function is shown Accept with YES The alarm is displayed Press YES to erase the alarm Accept with YES Return to running mode press MON 26 SEP 2016 U10 11 35 L12 11 ALARMS 09 AUG 15 52 NO RADIO MON 26 SEP 2016 U10 11 35 L12 11 ALARMS ERASE ALARMS ERASE ALARMS ERASE ...

Страница 19: ...larm LED lit General alarm relay activated Impulse current on output no 2 is below alarm limit Check output connections If OK clear the alarm CURRENT LOW 63 Red alarm LED lit General alarm relay activated Impulse current on output no 3 is below alarm limit Check output connections If OK clear the alarm CURRENT LOW 64 Red alarm LED lit General alarm relay activated Impulse current on output no 4 is...

Страница 20: ...lid for a specific date Group A group of programs signal events Type of signals There are some different kinds of signals depending on how the relay output is to be used ON OFF Is used when a longer lasting switching ON is required e g for controlling fans door locks lighting etc 01s Is used when a short pulse is required e g for bells buzzers Pulse duration selectable from 1 99 seconds Astr Astr ...

Страница 21: ...33 Tel 46 506 48000 Internet http www westerstrand se SE 545 23 TÖREBODA Fax 46 506 48051 E mail info westerstrand se To simplify programming 3 sub menus are used To enter new programs To erase a separate existing program To change existing programs WEEK PROGRAM NEW GROUP A WEEK PROGRAM ERASE GROUP A WEEK PROGRAM CHANGE GROUP A ...

Страница 22: ...g accept using YES Select output using Move to the right using State type of signal using State the days the program shall function using Move to the right using State the time of the program using Move to the right using Accept using YES If the program is approved the text Program saved is displayed quickly Continue with programming OFF for the same output or leave programming by pressing several...

Страница 23: ...ds Select function using Enter programming mode using YES Select change program using YES Select group of programs using accept using YES Select output using Move to the right using Step forward to the program which is to be changed using NO and YES Change the time to 09 15 using the arrows Accept using YES Leave the programming by pressing several times MON 26 SEP 2016 U10 11 00 L12 11 WEEK PROGR...

Страница 24: ...deleted Signal length is 5 seconds Select function using Enter programming mode using YES Select erase program using YES Select group of programs using accept using YES Select output using Move to the right using Step forward to the program that is to be erased using NO and YES Accept using YES Leave the programming by pressing several times MON 26 SEP 2016 U10 11 00 L12 11 WEEK PROGRAM WEEK PROGR...

Страница 25: ...ction using Enter programming mode using YES Select new program using YES Select group of programs using accept using YES Select output using Move to the right using State type of signal using State the days the program shall function using Accept using YES If the program is approved the text Program saved is displayed quickly Leave the programming by pressing several times MON 26 SEP 2016 U10 11 ...

Страница 26: ...g accept using YES Select output using Move to the right using State type of signal using State the days the program shall function using Move to the right using State the time of the program using Move to the right using Accept using YES If the program is approved the text Program saved is displayed quickly Continue with programming OFF for the same output or leave programming by pressing several...

Страница 27: ...lect group of programs using accept using YES Select output using Move to the right using State type of signal using 05S Pulse with 5 seconds length State the days the program shall function using Move to the right using State the time of the program using every hour Move to the right using Accept using YES If the program is approved the text Program saved is displayed quickly Leave programming by...

Страница 28: ...ct output using Move to the right using State type of signal using State the date the program shall function using Move to the right using State the time of the program using Move to the right using Accept using YES If the program is approved the text Program saved is displayed quickly Continue with programming OFF for the same output or leave programming by pressing several times MON 26 SEP 2016 ...

Страница 29: ...strand se Display Program Select function using Enter display program using YES Select program group using accept with YES Select output to be displayed using accept with YES Step forwards alt Backwards using Leave the function display program by pressing several times MON 26 SEP 2016 U10 11 00 L12 11 DISPLAY PROGRAM GROUP A OUTPUT ALL OUTPUT 2 ON MTWTF 08 00 00 DISPLAY PROGRAM MON 26 SEP 2016 U10...

Страница 30: ... turn off according to normal week program The temporary program will automatically be erased when the event has been effected Select function using Enter programming mode using YES Select output using Move to the right using State type of signal using Accept using YES Accept using YES or change the time of the program using Leave the programming by pressing several times MON 26 SEP 2016 U10 11 00...

Страница 31: ...ed during the school season and another used during school holidays School season Group A School holidays Group B The school holidays are at the following dates 1 5 10 6 15 8 23 9 and so on Select function using Enter programming mode using YES Select group of programs using accept using YES State the date when the period shall begin Move to the right using State the date when the period shall end...

Страница 32: ... is needed Select function using Accept with YES Press NO until wished function is shown Accept with YES Show status information of the different output input in the Master Clock Language selection Setup configuration of the different impulse system type of synchronisation etc Display format in running mode Present software version Default value used when pressing button ADV or REV Return to runni...

Страница 33: ...tatus of the synchronisation source receiver Select function using Accept with YES Press NO until wished function is shown Accept with YES Press NO until wished input output is shown Accept with YES The Master Clock has accepted 60 of the synchronisation messages Last reception was 14 10 19 59 00 Return to running mode press MON 26 SEP 2016 U10 11 35 L12 11 SPEC FUNCTIONS SPEC FUNCTIONS STATUS STA...

Страница 34: ...23 TÖREBODA Fax 46 506 48051 E mail info westerstrand se Status sync source Remark For W GPS the marked position always shows the actual second This information is updated every other second Status impulse output IL 0 5 12 00 UF 26 V Impulse current Impulse voltage Slave Clock time NMEA RS485 60 01 MAY 12 00 00 of accepted messages Last reception was 01MAY12 00 00 Type of synchronisation ...

Страница 35: ...E mail info westerstrand se Language With this function the language be selected Example Select function using Accept with YES Press NO until wished function is shown Accept with YES Select by using the arrows the wished language Accept with YES Return to running mode press MON 26 SEP 2016 U10 11 35 L12 11 SPEC FUNCTIONS SPEC FUNCTIONS LANGUAGE LANGUAGE ENGLISH MON 26 SEP 2016 U10 11 35 L12 11 SPE...

Страница 36: ...Example Set the alarm limit for synchronisation source alarm to 1 hour Default setting is 12 hours Select function using Accept with YES Press NO until wished function is shown Accept with YES Press NO until wished input output is shown Accept with YES Set by using the arrows the alarm limit to 1 hour 01h Accept with YES Return to running mode press MON 26 SEP 2016 U10 11 35 L12 11 SPEC FUNCTIONS ...

Страница 37: ...s needed Type of synchronisation State type of external synchronisation The following time sources can be selected NMEA RS485 default Synchronisation using RS485 input and NMEA ZDA protocol NMEA RS232 Synchronisation using RS232 input and NMEA ZDA protocol W GPS Radio synchronisation GPS type Westerstrand DCF77 Radio synchronisation DCF77 TC Time code type hard wired DC No external synchronisation...

Страница 38: ...lse with 12 hours resetting 1 2M 24H Polarised 1 2 minute impulse with 24 hours resetting 1 2M 12H Polarised 1 2 minute impulse with 12 hours resetting SEC 12H Polarised Second impulses with 12 hours resetting SEC 60S Polarised Second impulses with 60 seconds resetting 1 2 SEC Polarised Second impulses with 60 seconds resetting TCmarine Time Code marine TC ext Time Code marine for TC Clocks diamet...

Страница 39: ...minute impulse 0 1s 9 9 s Second impulses 0 1 1 0 s Alarm limits Impulse current low limit Alarm limit for low current minimum load The minimum load can be set from 0A up to 2 0A Impulse current high limit Alarm limit for high current maximum load The maximum load can be set from 0A up to 2 0A Impulse feedback voltage limit Alarm limit for feedback impulse voltage No limit default 01 99 Limit in v...

Страница 40: ... module The following protocols are available NMEA output from Master Clock NMMI NMEA 0183 ZDA Time string minute update without hundreds of seconds NMSE NMEA 0183 ZDA Time string second update without hundreds of seconds NMMC NMEA 0183 ZDA Time string minute update with hundreds of seconds NMSC NMEA 0183 ZDA Time string second update with hundreds of seconds NMin NMEA 0183 ZDA Time string input t...

Страница 41: ...fo westerstrand se No of stop bits 1 or 2 Available formats 7N1 7N2 7O1 7O2 7E1 7E2 8N1 8N2 8O1 8O2 8E1 8E2 Protocol description ZDA Time Date UTC Day Month Year and Local Time Zone 1 2 3 4 5 6 7 ZDA hhmmss ss xx xx xxxx xx xx hh CR LF Field Number 1 Universal Time Coordinated UTC 2 Day 01 to 31 3 Month 01 to 12 4 Year 5 Local zone description 00 to 13 hours 6 Local zone minutes description same s...

Страница 42: ...me 1 summer time 3 1 Synced from Radio source e g DCF77 2 1 Synched from timeserver 1 0 Type of time OFF OFF UTC OFF ON LOC ON OFF NOR Example Assume wintertime time synched from radio source synchronized from timeserver local time Bits 6 3 2 and 0 are set 0100 1101 4Dh M G UTC offset during wintertime from letter P in 1 2 hour steps Example Germany 2 x 1 2 1 hour so P 2 R W Weekday 1 Monday 7 Sun...

Страница 43: ...ank 20H DD Date 01 31 2FH MN Month 01 12 YY Year 00 99 NNN Daynumber 001 365 3 bytes W Weekday 1 7 CR 0DH LF 0AH At second 60 0 a synchronisation sign SUB 1AH is transmitted Remark The message transmitted at second 56 is next minute Example At 09 07 56 is a message transmitted The time included in this message will be 09 08 00 Protocol 5 T YY MN DD WW HH MM SS CR LF 24 bytes T T 3AH YY Year 00 99 ...

Страница 44: ... VV YYYY MN DD HH MM SS F G BCC ETX 24 bytes STX 02h 1 byte WW Week number 01 53 VV Weekday 01 07 YYYY Year 2003 2099 MN Month 01 12 DD Day 01 31 HH Hour 00 23 MM Minute 00 59 SS Second 00 59 F 0 Winter time 1 Summer time G Offset to UTC for winter time according to 1 byte 2Ch 2 hours 2Eh 1 hour 0 30h 0 hour BCC Checksum Exclusive OR of bytes WW F G in hexadecimal ascii format 2 bytes Byte STX is ...

Страница 45: ...TC Start Transmission Character 02 H Ten UTC hours 30 32 H Unit UTC hours 30 39 M Ten UTC minutes 30 35 M Unit UTC minutes 30 39 S Ten UTC seconds 30 35 S Unit UTC seconds 30 39 D Ten date UTC 30 33 D Unit date UTC 30 39 MO Ten month UTC 30 31 MO Unit month UTC 30 39 Y Ten year UTC 30 39 Y Unit year UTC 30 39 HL Ten LT hours 30 32 HL Unit LT hours 30 39 ML Ten LT minutes 30 35 ML Unit LT minutes 3...

Страница 46: ...is enabled the relay is activated every day for 5 seconds at 02 00 UTC Use the procedure below to enable the special pulse Select function using Accept with YES Press NO until wished function is shown Accept with YES Press NO until wished input output is shown Accept with YES Change to using Accept with YES Return to running mode press MON 26 SEP 2016 U10 11 35 L12 11 SPEC FUNCTIONS SPEC FUNCTIONS...

Страница 47: ... Example DEFAULT LT ADJ is set to 20 minutes Local Time is 15 30 1 Received LT is changed 5 minutes to 15 35 which is closer to 15 30 than 15 50 Master Clock LT will stay on 15 30 2 Received LT is changed 10 minutes to 15 40 which is in the middle of 15 30 and 15 50 Master Clock LT will stay on 15 30 3 Received LT is changed 15 minutes to 15 45 which is closer to 15 50 than 15 30 Master Clock LT w...

Страница 48: ...ows the software version for the Time Base module Select function using Accept with YES Press NO until wished function is shown Accept with YES The software version is MMC A127 11m Uptime for this Master Clock Return to running mode press MON 26 SEP 2016 U10 11 35 L12 11 SPEC FUNCTIONS SPEC FUNCTIONS SOFTWARE VERSION MON 26 SEP 2016 U10 11 35 L12 11 SPEC FUNCTIONS SOFTWARE VERSION MMC A127 11m SPE...

Страница 49: ...s used to enter the default value used when pressing button ADV or REV Example Change default LT adj from 60 minutes to 20 minutes Select function using Accept with YES Press NO until wished function is shown Accept with YES Change to using Accept with YES Return to running mode press MON 26 SEP 2016 U10 11 35 L12 11 SPEC FUNCTIONS SPEC FUNCTIONS DEFAULT LT ADJ MON 26 SEP 2016 U10 11 35 L12 11 SPE...

Страница 50: ...lected Format 1 LT Local Time UTC Universal Time Coordinated Format 2 Default L Local Time U UTC Format 3 Used for test fault finding Example Select function using Accept with YES Press NO until wished function is shown Accept with YES Select by using the arrows the wished display format Accept with YES Return to running mode press MON 26 SEP 2016 10 11 00 LT MON 26 SEP 2016 LT MON 26 SEP 2016 U10...

Страница 51: ...Manual Date 2017 12 22 Page 48 of 51 WESTERSTRAND URFABRIK AB P O Box 133 Tel 46 506 48000 Internet http www westerstrand se SE 545 23 TÖREBODA Fax 46 506 48051 E mail info westerstrand se Programming form Function Group Output no Type of signal Day Date Time ...

Страница 52: ...ime the time shown by the slave clocks Relay outputs are programmed but nothing happens C1 The switch on the front panel is in position 0 Correct position is A C2 Check that the output is working when the switch is in position 1 C3 Different program types have different priority E g a programmed date program overrides a signal point in a week program Priority order 1 highest 3 lowest 1 Date progra...

Страница 53: ...ot programmed When trying to change a non existing signal point Alarm output The Master Clock is equipped with two separate alarm relays One relay for general alarm and one for power failure alarm See alarm list on page 16 for details General alarm 1 2 1 3 Normal mode no alarm Open Closed Overload short circuit alarm Closed Open Synchronisation alarm Closed Open Power alarm 8 9 8 10 Normal mode no...

Страница 54: ...WARD LT COMMON LT REVERSE LT FORWARD LT COMMON LT REVERSE LT FORWARD PIN NO 2 4 3 1 IMPULSE OUTP 4 SIGNAL LT FORWARD LT COMMON LT REVERSE 5 7 6 9 10 8 05 3 WIRE 12 11 12 NO CONNECTION 10 9 11 IMPULSE 4B NO CONNECTION IMPULSE 4A SIGNAL 2 4 3 IMPULSE 4B IMPULSE 4A NO CONNECTION 1 IMPULSE 4A PIN NO 05 2 WIRE IMPULSE OUTP 4 5 7 6 IMPULSE 4A NO CONNECTION IMPULSE 4B 8 IMPULSE 4B 6 TX 8 6 4 5 7 2 1 3 SI...

Страница 55: ...e 2009 11 04 Page 1 of 5 WESTERSTRAND URFABRIK AB Box 133 Tel 0506 48000 Internet http www westerstrand se 545 23 TÖREBODA Fax 0506 48051 E mail info westerstrand se WIRED DCF TIME CODE CLOCK Max 400 mm in diameter for Time zone adjustment TECHNICAL MANUAL ...

Страница 56: ...lock is intended for time zone adjustment from a Marine master clock Installation Connect Time code to time code input connection movement The hands will step forward to 12 position and wait there for correct time message The speed is approx 1 step sec When an accepted Time message the hands will step forward to correct time If the Marine master clock sends out a special time message Time zone adj...

Страница 57: ... TÖREBODA Fax 0506 48051 E mail info westerstrand se Technical data Art no 113160 20 113160 22 113163 20 113163 22 Connection 2 wire Connection voltage 24VDC combined with serial Time Code Type of time code DCF format with Time zone adjustment Microcontroller PIC16F628 Temperature range 20 C to 50 C Power consumption 20 mA 113160 20 113160 22 30 mA 113163 20 113163 22 ...

Страница 58: ...oc INTELLIGENT CLOCKS Author TAn Date 2009 11 04 Page 4 of 5 WESTERSTRAND URFABRIK AB Box 133 Tel 0506 48000 Internet http www westerstrand se 545 23 TÖREBODA Fax 0506 48051 E mail info westerstrand se 113160 20 113160 22 ...

Страница 59: ...KS Author TAn Date 2009 11 04 Page 5 of 5 WESTERSTRAND URFABRIK AB Box 133 Tel 0506 48000 Internet http www westerstrand se 545 23 TÖREBODA Fax 0506 48051 E mail info westerstrand se 113163 20 TC 39 4 4 Ø3 Ø1 4 5 17 5 5 M13x1 87 5 113163 22 ...

Страница 60: ...RAND Author PM Date May 8 2014 Page 1 of 11 WESTERSTRAND URFABRIK AB P O Box 133 Tel 46 506 48000 Internet http www westerstrand se SE 545 23 TÖREBODA Fax 46 506 48051 E mail info westerstrand se Option Ethernet Marine Master Clock ...

Страница 61: ...sterstrand se List of contents List of contents 2 General 3 Link indicator 3 Technical data 3 Configuration 4 Status IP 5 Work mode NTP Server or Client 5 WEB browser 6 Login window 6 Status 7 General 8 Network 9 DHCP 9 IP 9 Gateway 9 Subnetmask 9 DNS 9 SNMP 9 SNMP server 9 NTP 10 NTP mode 10 Broadcast Multicast Server Interval s 10 NTP server 1 5 10 Interval s 10 Max correction s 10 Help 11 Techn...

Страница 62: ...Master Clock via the network module Included with the Ethernet module is NyToP Westerstrand NTP client for Windows 98 NT 2000 XP Vista For remote control and relay programming the windows based application software QW3Control can be used The QW3Control is an option To configure the different parameters such as IP address work mode etc a normal WEB browser is used Link indicator The front panel of ...

Страница 63: ...er Clock by using the special function setup IP address The following parameters can be viewed from the Master Clock by using the special function status IP address Example Give the module IP address 192 168 1 66 Select function by using Accept using YES Press NO until wished function is displayed Accept using YES Press NO until the text IP is displayed Accept using YES Set by using the arrows the...

Страница 64: ...tivity indicator A Showing the network traffic from to the Master Clock Work mode NTP Server or Client The network module kan work in two different modes Server The Master Clock works as a NTP time server answering to NTP requests from NTP clients Client Server The Master Clock is both NTP client and NTP server The work mode is set from the Master Clock SPEC FUNKTIONS SETUP SYNC SOURCE SYNC SOURCE...

Страница 65: ... Box 133 Tel 46 506 48000 Internet http www westerstrand se SE 545 23 TÖREBODA Fax 46 506 48051 E mail info westerstrand se WEB browser Login window The Web interface requires a password Always use user name admin and a valid password Default password is password After login a function list is displayed ...

Страница 66: ...4 Page 7 of 11 WESTERSTRAND URFABRIK AB P O Box 133 Tel 46 506 48000 Internet http www westerstrand se SE 545 23 TÖREBODA Fax 46 506 48051 E mail info westerstrand se Status Displays the Master Clock status The status is automatically updated every 10th second ...

Страница 67: ...Internet http www westerstrand se SE 545 23 TÖREBODA Fax 46 506 48051 E mail info westerstrand se General To set general parameters Name Symbolic name maximum 48 characters Example Station Master Clock Password Enter a new password The password has to be repeated Firmware Function to enable firmware download Save Save parameters ...

Страница 68: ... if the Ethernet modules should receive its IP address automatically from a DHCP server or use the static IP address IP This function is used to give the Ethernet module a static IP address Gateway This function is used to enter a gateway IP address Subnetmask This function is used to enter a subnetmask DNS This function is used to enter a name server IP address SNMP With this code the SNMP functi...

Страница 69: ...ient network clocks will show a new time quicker Make sure the client clock has enabled broadcast multicast e g NTP mode Broadcast Multicast Also Country Timezone Local Time must be selected in the client clock Timebase With this function the type of time transmitted in the NTP message is chosen Default UTC NTP server 1 5 This function is used if the Time Central is receiving time from an external...

Страница 70: ...ttp www westerstrand se SE 545 23 TÖREBODA Fax 46 506 48051 E mail info westerstrand se Help Used to view a pdf help file Technical remark When option Ethernet is mounted and synchronisation source NMEA RS485 is selected the RS485 output can only be used for transmission of NMEA ZDA time string with fixed baudrate 4800 and data format 8N1 ...

Страница 71: ...LCD To facilitate time zone change there are 2 separate buttons for this purpose The master clock also has a dimmer to adjust background illumina tion Technical data Crystal frequency 4 915200 MHz Accuracy 0 1 sek 24 hours 20C Microprocessor HD6412394 Time memory 30 days Back up with Super Capacitor Ambient temperature 0 C to 50 C Relative humidity Max 85 non condensing Case 19 case according to d...

Страница 72: ...e 0 1 9 9 sec Second 0 1 1 sec Output 3 Impulse system 1 1 minute 1 2 minute second 1 2 second time code TC Type of time LT UTC Impulse length Minute 0 1 9 9 sec Second 0 1 1 sec Output 4 Impulse system 2 wire 1 1 minute 1 2 minute second 1 2 second time code TC 3 wire for forward forward back 1 1 minute alt 1 2 minute Type of time LT UTC Impulse length Minute 0 1 9 9 sec Second 0 1 1 sec Max load...

Страница 73: ...put Relay output no 2 can be dedicated to send out a special pulse When this function is enabled the relay is activated every day for 5 seconds at 02 00 UTC Telegraph Logger Clock signal If one of the impulse outputs is configured to work as telegraph logger clock signal 1 2M 12B then relay out put no 2 is used to send out a Counter C W signal and can not be used for other purposes Alarm output Nu...

Страница 74: ...can be used to synchronise the master clock with an external time source pro vided with RS232 or RS485 output The purpose of this is to achieve higher accuracy Protocol data format and baud rate is selectable for respective serial port Serial output Baud rate selectable 300 600 1200 2400 4800 9600 19200 baud Data format selectable 7N1 7N2 7O1 7O2 7E1 7E2 8N1 8N2 8O1 8O2 8E1 8E2 No of data bits 7 o...

Страница 75: ...compensation for low input voltage With option DC DC the DC input will be galvanic isolated and low high input voltage is compensated automatically Supply voltage 90 264V 50 60 Hz and 24VDC Option DC DC Galvanic isolated Input voltage 19 36VDC Output voltage 23 30VDC adjustable Isolation voltage 1500V Power consumption AC 65W DC 50W Options DC DC converter Ethernet LAN connection GPS receiver Tabl...

Страница 76: ......

Страница 77: ...Analog clocks minute 3 wire F R 400 mm 10 mA Digital Clocks 5 mA Time Code TC Slave Clocks Analog clocks minute 400 mm 14 mA version with movement 113160 00 Analog clocks minute 400 mm 7 mA version with movement 21634 00 Analog clocks minute 900 mm 20 mA Analog clocks minute sweep seconds hand 400 mm indoor 12 mA Analog clocks minute sweep seconds hand 400 mm outdoor 20 mA Analog clocks minute swe...

Страница 78: ......

Страница 79: ...el reserves the right to modify designs and alter specifications without notice ZENITEL PROPRIETARY This document and its supplementing elements contain Zenitel or third party information which is proprietary and confidential Any disclosure copying distribution or use is prohibited if not otherwise explicitly agreed in writing with Zenitel Any authorized reproduction in part or in whole must inclu...