Exigo Network Amplifier for Rolling Stock ENA2060-DC1
Installation & Configuration Manual
A100K11689
Страница 1: ...Exigo Network Amplifier for Rolling Stock ENA2060 DC1 Installation Configuration Manual A100K11689...
Страница 2: ...3 1 Ethernet Ports 1 2 5 3 2 Status Indicators 5 3 3 Activity Indicators 5 3 4 Multi Connector 6 3 5 Audio Line Connector 7 3 6 Grounding Stud 7 3 7 Power Connector 7 4 Configuration 8 4 1 Main Settin...
Страница 3: ...aker line technology ease of cabling with galvanic separation Supports direct audio routing to wide range of induction loop amplifiers Designed manufactured and tested according to EN50155 and EN45545...
Страница 4: ...arriage For the rolling stock environment it is considered good practice to mount support rails to better secure the amplifier Use six 5 mm diameter bolts M5 that are suitable for the mounting surface...
Страница 5: ...LED is lit when the amplifier is connected to the network Activity Yellow LED is lit when data is being transmitted 3 2 Status Indicators The status indicators display the status of important paramet...
Страница 6: ...DC Signal Output physical volume controller override 9 GPO2 0 VDC Signal Output 10 UIC IN UIC Audio Signal Input 11 UIC IN 12 GPI2 General Purpose Inputs PTT key or audio triggered by other equipment...
Страница 7: ...0V Audio Channel Outputs Monitoring Signals 3 6 Grounding Stud This is an M4x20 stud for fixing a tab to the chassis and grounding the amplifier If the amplifier isn t connected to ground it will not...
Страница 8: ...server an IP address in the range 169 254 x x will be assigned To be able to hear the amplifier announce its IP address 1 Either connect a 100 V speaker to Channel 1 on the 100V Audio Line see sectio...
Страница 9: ...s Static IP or DHCP o IP address 10 5 11 160 example IP address of Amplifier o Subnet mask 255 255 255 0 o Gateway 10 5 11 1 NTP Settings o Enable NTP Check the box to enable NTP o Hostname 10 5 2 19...
Страница 10: ...10 Exigo ENA2060 DC1 Amplifier Installation Configuration Manual A100K11689 4 2 SIP Settings Select SIP Configuration SIP Settings...
Страница 11: ...Optional This is the tertiary SIP Server Domain used as backup in case both the primary and secondary domains fail Authentication Username This is the authentication user name used to register the amp...
Страница 12: ...n be queued before hanging up RTP Timeout This cancels a PA call if the amplifier does not receive RTP packets from the remote party Enter values in the range 0 9999 seconds The default setting is 0 w...
Страница 13: ...ter speaker line measurements for any significant changes that will cause line fault reporting After the calibration the speaker line load must not be changed or else false fault messages may be repor...
Страница 14: ...ction Any faults reported will be removed if subsequent SLM measurements result in an ok state or if the Reset Calibration button is clicked Channel Disable Click to switch OFF the amplifier output fo...
Страница 15: ...nt 1045 1370 1365 435 1065 400 1500 Phase 1075 765 925 1545 975 400 1500 Ground Fault 405 405 405 405 405 1580 4 5 Firewall Settings To be able to upload configuration data the amplifier network port...
Страница 16: ...from the amplifier web interface 1 Start the TFTP server program and set the server path by browsing to the directory where the configuration file is located 2 Log on to the amplifier web interface 3...
Страница 17: ...e TFTP Server and download the software Install the TFTP Server program on your PC Follow the procedure below to upgrade the amplifier software 1 Start the TFTP server program and click Browse to sele...
Страница 18: ...message TFTP_CONN_ERROR is displayed If the response is TFTP_CONN_OK the settings are saved and the Upgrade button will appear 7 Click the Upgrade button to upgrade the software on the amplifier The u...
Страница 19: ...mum audio output poe_audio 1 Use RFC2833 to send DTMF dtmf_style 1 Disable tones tone_volume 1 Use PTT as default speech mode speech_mode 1 auto answer enabled auto_answer_mode 1 reduced mic sensitivi...