flowSCREW 4w
packages
Copyright Vincotech
Handling Instruction
03
rem. sect. 5.2; mod. at sect. 5.1 29.09.2014
Gyimóthy Zs.
Gyetvai T.
FSWB-M-*-HI
Page
12 /
18
02
remove section 6.2
14.05.2014
Gyimóthy Zs.
Gyetvai T.
01
20.02.2014
Gyimóthy Zs.
Gyetvai T.
Ver.
Alteration
Date
Des. / Mod.
Appr.
8.2 Interconn PCB
If you wish to operate modules in parallel, mount an Interconn PCB to the side connectors (see
Figure 11
) after the modules are attached to the heatsink. Use M4 hex nut holders with the
following components and torque to fasten it to modules' side connectors:
M4 screws
Mounting torque: 2 < Ma < 2.2 Nm
Flat washer: ISO 7092 (DIN 433)
Spring washer: DIN 127 or DIN 128
Please contact the local sales or distribution office to learn more about Interconn PCBs and
ordering codes.
Figure 10: Interconn PCB