Viale Vicenza 14
36063 Marostica VI - Italy
www.vimar.com
20196-03996-03997EN 04 2012
03996
03997
Eikon
20196
Arké
19196
Plana
14196
20196, 19196, 14196 - Quid electronic switch for roller shutter with
slat orientation with relay outputs for cos
φ
0.6 motor 2 A 220-240 V~
50/60 Hz, position saving.
03996 - Quid electronic relay module for roller shutter with slat orien-
tation with relay outputs for cos
φ
0.6 motor 2 A 220-240 V~ 50/60 Hz,
position saving, installation in junction boxes or connector block boxes.
The device is designed to control a load such as a roller shutter, shutter or curtain
while also allowing the adjustment of the position of the roller shutter or slats. It
is available in the version with 1-module double push button to match the Eikon,
Arké and Plana wiring series or for retrofit controlled by double push button. The
devices can be connected together and managed from a single centralised control.
The favourite roller shutter position can be saved and recalled starting from any
initial position.
03997 - Quid roller shutter control unit module, 2 inputs for NO push
button, 6 outputs for Quid roller shutter relay module 03996, 220-240
V 50/60 Hz power supply, installation in junction boxes or connector
block boxes.
The device, which can be installed inside connector block boxes, is designed to
manage several groups of roller shutters and control them from a single point.
CHARACTERISTICS of art. 20196, 19196, 14196 and 03996.
•
Rated supply voltage: 220 – 240 V~ 50/60 Hz.
•
Absorption: 13 mA.
• Relay output
• Controllable loads at 220-240 V~:
- resistive loads
: 5 A (20,000 cycles);
- cos ø 0.6 motors: 2 A (20,000 cycles).
• Double push button for art. 20196-19196-14196
• LED for load status indication and programming.
• Terminals:
- motor
(UP) and
(DOWN) relay contacts
- line L
- neutral N
- C
and C
group control input to connect to art. 20062-19062-14062. For
art. 20196-19196-14196 additional local control input using art. 03997.
- in art. 03996 dedicated P
and P
input for local control (for instance art.
20062-19062-14062, 20066-19066-14066).
• Number of roller shutters that can be connected: max. 20
• Max. length of cables for each section: 50 m
• Possible functions:
- roller shutter/curtain position adjustment.
- slat position adjustment.
- saving and calling of favourite roller shutter/curtain position starting from any
initial position.
- control from interlocked or non-interlocked double push button.
•
Dissipated power of art. 03996: max. 1 W.
•
In the event that several roller shutter relays are connected using control unit
module 03997, the system must be set up with a single Hysteresis and/or
RCBO circuit breaker.
• It should be used in dry, dust-free places at a temperature of between 0 °C and
+45 °C.
Art. 03997 CHARACTERISTICS.
• Rated supply voltage: 220 – 240 V~ 50/60 Hz.
• Control via interlocked or non-interlocked double push button.
• In combination with art. 20196-19196-14196 is designed to insert an additional
local control.
• Designed to control 3 groups of roller shutters.
• Number of roller shutters that can be connected: max. 20
• Number of group levels: max. 3
• Max. length of cables for each section: 50 m
• It should be used in dry, dust-free places at a temperature of between 0 °C and
+45 °C.
CONFIGURATION of art. 20196,19196,14196 and 03996.
Configuration is done using the device dip switch and the control push buttons
(see figures 20196-19196-14196 and 03996).
N.B. For art. 03996 switch off the
power supply before accessing the device and operating the dip switches.
TIMING
The relay is set by default with an operating time of 120 s; to modify this value,
proceed as follows:
• Lower the roller shutter/curtain until you reach the limit stop
• Position the dip switch on
SET
; the LED begins to flash (if you press
(
DOWN
)
nothing happens)
• Press and hold down
(
UP
) to raise the roller shutter/curtain; the LED is perma-
nently lit.
• Once the roller shutter/curtain reaches the limit stop, briefly press
(
DOWN
) or
(
UP
).
• The LED starts to flash again and the roller shutter/curtain moves
DOWN
for 1 s
and
UP
FOR 1 S.
• Replace the dip switch in the
OFF
position; the LED goes out.
FAVOURITE POSITION
Important: to make this setting you first need to have completed the TIMING
procedure.
• Take the roller shutter/curtain to your favourite position.
• Press
(
UP
)/
(
DOWN
) for 3 s or press briefly
(
UP
) or
(
DOWN
) 5 times;
the roller shutter/curtain moves
DOWN
for 1 s and
UP
for 1 s to confirm the
setting.
RESET
Shift the dip switch from the
OFF
position to the
SET
position to reset all the set-
tings made.
In the event of a power failure, all the settings remain saved.
LOCAL AND GROUP CONTROL BUTTON FUNCTIONS.
•
Press and hold down (for more than 1 s) = roller shutter/curtain opening/closing.
•
Press briefly (less than 1 s) = slat adjustment.
•
Press
(
UP
) or
(
DOWN
) briefly twice = recalls the favourite position.
INSTALLATION RULES.
•
Installation must be carried out by qualified persons in compliance with the cur-
rent regulations regarding the installation of electrical equipment in the country
where the products are installed.
•
The power supply circuit (L-N) must be protected against overloads by installing
a C10 A automatic 1-way switch.
•
Art. 03996 and 03997 can be installed inside junction boxes provided they have
been declared suitable for electrical devices that dissipate energy.
REMOTE CONTROL RECEPTION.
Quid can be remote controlled using the following devices:
•
video door entry system: Video Door App + art. 40507 + art. 69RH or
69PH (programmed for 2 s timed actuation)
The system is designed to configure a timed actuation (relay art. 69RH
or 69PH) and control it from video door entry indoor stations. If the indoor station
is connected (art. 40507) actuation can be remote controlled via the Video Door
App.
•
IP video door entry system: Video Door App + art. 40607 + art. 40636 (pro-
grammed for 2 s timed actuation)
The IP video door entry system is designed to configure a timed actuation (relay
art.40636) and control it from video door entry indoor stations. If the indoor sta-
tion is connected (art. 40507) actuation can be remote controlled via the Video
Door App.
•
GSM thermostat 01913:
the device is fitted with a programmable output to
which an auxiliary supporting relay needs to be connected (a common one-posi-
tion stable relay with a 230V coil is sufficient). Actuation is then controlled via the
By-Phone App or the By-Clima App (or directly via SMS text message).
REGULATORY COMPLIANCE.
LV Directive. EMC directive. EN 60669-2-1 standard.
REACH (EU) Regulation no. 1907/2006 – Art.33. The product may contain traces