3 Installation Villagepump 500 Standard
The Villagepump 500 Standard is suitable for low or average polluted surface water,
rainwater harvesting, ponds and streams.
Please note that:
- the bottom of the Villagepump should be mounted not more than 3 meters above the
water level (maximum static head of 3 meter);
- the length of the Inlet Hose that is included in the delivery, is 10 meter. This is the
maximum distance to be covered with the priming system of the Villagepump.
- Install the Villagepump on a flat, hard (concrete, metal, wood) smooth and level surface,
with a minimum size of 60 by 120 cm.
- A Foot Plate / Installation Frame is delivered together with the Villagepump 500 Standard,
with the studs (M8) at the right position (distance 40 x 25 cm). This footplate should be
mounted on a sturdy, flat floor or can be moulded in a cement of concrete base. If you
choose this option, please take care that the bolts are at least 45 mm above the surface of
the cement/concrete base.
Installation Plate / Foot Plate with four M8 rods
- Apply the supplied spacers (length 3 cm) to the studs / bolts; place the Villagepump over
the studs / bolts and secure it with four self-locking M8 nuts. The Villagepump is now firmly
anchored to the floor.