O&M Manual v.1.42 October 2017
19
Installing Activated Carbon cartridge
6.5 Replacing UF Membrane
Replace the UF Membrane every 2
– 5 years, depending on the quality of the inlet water
acoording instructions below.
- Remove the lock and open the cover
- Remove the hook from the valve
- Carefully pull the UF membrane out of the valve
- Carefully unpack the new UF membrane
- Remove the caps from the connectors
- Lubricate the 0-rings of the terminals with Silicon Compound (included in first delivery of the
Villagepump)
- Pressure the UF membrane carefully in the block as far as the stop, the bottom side of the
membrane rests on the lower console.
- Lock the membrane with hook and tighten the nut
- Carry out two back-wash cycles to remove the Glycol that is used for conservation of the
UF Membrane. Note that the AC Cartridge is removed during these two first cycles.