O&M Manual v.1.42 October 2017
10
Connecting drain hose (B):
- Mount the Hose Nipple to the plastic part inside the Villagepump firmly.
- Fit the Drain Hose (1 meter length is delivered standard) as far as possible on the Hose
Nipple and connect the hose firmly with a hose clamp (B).
4.3 Connecting Mesh Filter
Note: shorten the Inlet Hose to the minimal length needed, especially when the water
level is 3 or more than 3 meters below the level of the Villagepump.
- Fit the Inlet Hose to the Mesh Filter using a Hose Clamp and connect it firmly. Check
carefully if the Mesh Filter is really connected well!
Note: please be aware that this connection should be completely air-tight because the
feed pump operates with a vacuum.
- Attach the Floater to the Mesh Filter with for instance a tie wrap (included in standard
delivery)
- Place the Mesh Filter in the water and make sure it is under water but not in mud or soil.
Mounting the Mesh Filter to the hose; connect the floater to the Mesh Filter with for instance a tie wrap
in order to keep Mesh Filter just below the water surface.
4.4 Assembling Activated Carbon cartridge (optionally)
Note: Activated Carbon (AC) filter cartridge is usually not installed. If the cartridge is
installed, remove AC filter cartridge before the first use. Every new UF Membrane is
shipped filled with Glycol to protect it from freezing. Glycol is harmful for the AC filter
cartridge. At least 3 backwash cycles are needed to be sure to dispense the UF
Membrane of all Glycol.