Viking Professional VCQS001SS Скачать руководство пользователя страница 1

9

Air Shutters

Orifice

1

½

(3.8 cm)

3/8”
(.95 cm)

F

FLLA

AM

ME

E    H

HE

EIIG

GH

HT

T

B

BU

UR

RN

NE

ER

R  A

AD

DJJU

US

ST

TM

ME

EN

NT

T

Each burner is tested and adjusted at the factory prior to shipment; however, variations in the local gas supply may

make it necessary to adjust the burners.  The flames of the burners should be visually checked and compared with flame
height drawing below.  

Flames should be blue and stable with no yellow tips, excessive noise or lifting.  If any of these conditions exist, check

if the air shutter or burner ports are blocked by dirt, debris, spider webs, etc.  With a proper flame height, adjust the air shutter
to obtain a blue flame with no yellow tipping that sits on the burner at the burner ports.  The air shutter is locked in place by a
set screw which must be loosened prior to lighting the burner for adjustments.

To access the air shutter on the side burners, remove the grates, burner bowls, and grate support.  With a screw

driver, loosen the lock-screw on the face of the air shutter.  Light the burner and adjust according to the directions below.

1.  If the flame is yellow, turn the air shutter counter clockwise to allow more air to the burner.
2.  If the flame is noisy and lifting away from the burner, turn the air shutter clockwise to reduce the amount of air to

the burner.

Once adjusted, turn the burner off, tighten the set screw on the air shutter, replace the grate support, burner bowls, and
grates.  To ensure proper installation of the side burners, slide opening in air shutters over the orifice located in the front of the
unit.

B

BA

AS

SIIC

C  S

SP

PE

EC

CIIF

FIIC

CA

AT

TIIO

ON

NS

S

D

DE

ES

SC

CR

RIIP

PT

TIIO

ON

N

Q

QS

SC

C3

30

00

0

Q

QS

SC

C4

41

12

2

Overall Width

61-3/4” (156.9 cm)

73-3/8” (186.4 cm)

Overall Height

37-5/8” (95.6 cm)

37-1/2” (95.3 cm)

Overall Depth

To end of landing ledge

31-5/8” (79.7 cm)

To end of knobs

33-3/8” (84.8 cm)

Gas Requirements

N/A

Natural:

Standard residential 1/2” (1.3 cm) ID
gas service line

LP/Propane:

Equipped with high capacity
hose/regulator assembly for
connection to standard 5 gal, 20 lb.
LP/Propane gas cylinder with Type 1,
QCC-1 connection or 
standard residential 1/2” (1.3 cm) ID
gas service line

Electrical Requirements

N/A

9 volt DC battery for electronic ignition

Surface Burner Rating

N/A

15,000 BTU Nat./13,500 LP/Propane
(4.4 kW Nat./4.0 kW LP/Propane)

Approx. Shipping Weight

170 lbs. (76.5 kg.)

275 lbs. (123.8 kg)

Отзывы: