DefendRx® 5000 
Electronic Air Purifier 

Installation Instructions 

 

Turn OFF the POWER to the Furnace/Air Handler and Fan switch. 

 

Open the door of the unit and remove the old pleated media (Fig.6). 

 

Position  the  new  5"  replacement  box  such  that  the  metal  mesh  on 
media faces the metal screen of the cabinet, the end with a hole goes 
in first, then push the box in strictly following the direction on labels 
on the box, (Fig.7). 

 

Close the door (Fig. 4 and Fig. 5). 

 

Switch the Power back ON. 

 

 

 

Fig. 6 

Fig. 7 

 

 

For Technical Assistance call: 1-800-565-5326 

Low Pressure Filter Media DefendRx 5000 5”  

 

OPERATION, INSTALLATION & MAINTENANCE 

INSTRUCTION  GUIDE 

 

IMPORTANT: Please complete the information below and leave this 
brochure with your customer after installation is complete. 

 

INSTALLED BY: 

 

Contractor Name & Phone No.:   

 

 
 

 

PRODUCT INFORMATION: 

 

MODEL: Viking DefendRx 5000 Electronic Air Purifier 
 
FILTER SIZE:   

 

 

INSTALLATION DATE:   

 

 

 

5" Polarized-Media 

Electronic Air Cleaner 

 

 

WARNINGS 

 

The air filter is not energized in the absence of air flow in the HVAC system. 

 

CAUTION  -  THE  AIR  CLEANER  SHALL  NOT  BE  INSTALLED  IN  A 
SYSTEM WITH AIR FLOW LESS THAN 375 CFM, TO ENSURE OZONE 
LEVELS ARE NOT EXCEEDED. 

 

THIS  AIR  CLEANER  SHALL  NOT  BE  INSTALLED  ON  THE  HOT-AIR 
SIDE OF DUCT-TYPE SYSTEMS. 

 

The POWER to the Furnace/Air Handler MUST BE TURNED OFF whenever 
installing, removing, or replacing the MicroPower Guard air cleaner. 

 

Failure  to  change  the  Replacement  Media  on  a  6-month  Basis  could  reduce 
airflow and cause damage to the heating and cooling system. 

 

Only qualified Electricians/HVAC Technicians should perform electrical wiring. 

When non-original DefendRx filter media is used, no matter what the makers 

claim, we are forced to decline your Lifetime Warranty. 

This product complies with the maximum allowable concentration of ozone of 0.050 parts 
per  million  by  volume  (ppmv)  in  a  24  h  period.  The  Health  Canada  Guideline  2010 
recommends that the maximum exposure limit, based on an averaging time of 8 hours, be 
0.020 ppmv or less when tested in an ASHRAE 52.2 conforming test duct. 