* Note:  

A keyless entry code can be programmed for 

EITHER

an unlimited number of uses or one time use, 

NOT

both. There can be a

maximum of 6 keyless entry codes and/or one time use keyless entry codes per entrance.

** Note:  

Only entry phone call waiting Caller ID will function in this mode, standard entry phone Caller ID will not.

*** Note:

The entry phone 1 position can not be programmed in the No Entry Phone Mode while the 

C-2000B

is in the Doorbell Mode

(DIP switch 1 ON, see page 9), as the Doorbell Mode relies on entry phone 1.  The 

C-2000B

will provide 3 error beeps if you attempt to

program “1#81” while DIP switch 1 is ON.

8

Description

Enter Digits

+

Location

Privacy Number (factory disabled) 

0-6 digits (0-9)

+

#00

Entry phone 1 keyless entry codes (factory disabled) 

4-6 digits (0-9)

+

#11 - #16

* Entry phone 1 one time use keyless entry codes (factory disabled) 

4-6 digits (0-9)

+

Q

#11 - 

Q

#16

Entry phone 2 keyless entry codes (factory disabled) 

4-6 digits (0-9)

+

#21 - #26

* Entry phone 2 one time use keyless entry codes (factory disabled) 

4-6 digits (0-9)

+

Q

#21 - 

Q

#26

Entry phone 3 keyless entry codes (factory disabled) 

4-6 digits (0-9)

+

#31 - #36

* Entry phone 3 one time use keyless entry codes (factory disabled) 

4-6 digits (0-9)

+

Q

#31 - 

Q

#36

Entry phone 4 keyless entry codes (factory disabled)

4-6 digits (0-9)

+

#41 - #46

* Entry phone 4 one time use keyless entry codes (factory disabled) 

4-6 digits (0-9)

+

Q

#41 - 

Q

#46

Master keyless entry codes (factory disabled) 

4-6 digits (0-9)

+

#51 - #56

* Master one time use keyless entry codes (factory disabled) 

4-6 digits (0-9)

+

Q

#51 - 

Q

#56

Door strike 1 activation time (.5 - 99 seconds, factory set to 5 seconds) 

2 digits (00-99)

+

#19

Door strike 2 activation time (.5 - 99 seconds, factory set to 5 seconds) 

2 digits (00-99)

+

#29

Door strike 3 activation time (.5 - 99 seconds, factory set to 5 seconds) 

2 digits (00-99)

+

#39

Door strike 4 activation time (.5 - 99 seconds, factory set to 5 seconds) 

2 digits (00-99)

+

#49

Door strike activation code (blank = disabled, factory set to 

QQ

)

1 or 2 digits 

+

#57

To program 

Q

as part of a relay command

QQ

Enable door strike buzz (factory setting)

1

+

#58

Disable door strike buzz 

0

+

#58

Maximum entry phone ring count (1 - 99 rings, factory set to 5 rings)

2 digits (01-99)

+

#61

Enable entry phone ringing (factory setting)  

1

+

#62

** Disable entry phone ringing 

0

+

#62

Enable global keyless entry

1

+

#66

Disable global keyless entry         (factory setting) 

0

+

#66

Enable # Conflict mode

1

+

#67

Disable # Conflict mode (factory setting)

0

+

#67

Caller ID, entry phone 1

1-15 digits 

+

#71

Caller ID, entry phone 2

1-15 digits 

+

#72

Caller ID, entry phone 3

1-15 digits 

+

#73

Caller ID, entry phone 4

1-15 digits 

+

#74

No Entry Phone mode enabled for entry phone 1***

1

+

#81

No Entry Phone mode disabled for entry phone 1 (factory setting)

0

+

#81

No Entry Phone mode enabled for entry phone 2

1

+

#82

No Entry Phone mode disabled for entry phone 2 (factory setting)

0

+

#82

No Entry Phone mode enabled for entry phone 3

1

+

#83

No Entry Phone mode disabled for entry phone 3 (factory setting)

0

+

#83

No Entry Phone mode enabled for entry phone 4

1

+

#84

No Entry Phone mode disabled for entry phone 4 (factory setting)

0

+

#84

Security code (factory set 845464)

6 digits (0-9)

+

#47

B.  Quick Programming Features 

(after accessing Programming Mode)

Содержание C-2000B

Страница 1: ...65 E 70 and E 75 Phones K 1500 7 Stainless Steel Panel Phone K 1700 3 and K 1705 3 Phone with Keypad K 1900 8 Stainless Steel Panel Phone with Keypad Or use with any analog touch tone phone Provides e...

Страница 2: ...Analog Station Mode DIP switch 5 ON DIP Switches see page 9 Power Input 13 8VAC 1 25A adapter included Note The C 2000B is not recommended to be installed in combination with the TR 1 Toll Restrictor...

Страница 3: ...Stations E 10A E 60 E 40 K 1700 3 Ring Gen Ring Gen Ring Gen Ring Gen Ring Gen Ring Gen Ring Gen Ring Gen Note Keypads used for keyless entry only Note A C O line is not required but the unit must be...

Страница 4: ...Electronic devices are susceptible to lightning and power station electrical surges from both the AC outlet and the telephone line It is recommended that a surge protector be installed to protect agai...

Страница 5: ...G CO LINE INPUT GND OUT TO PHONES USB USB TRIG 1 TRIG 2 TRIG 3 TRIG 4 MSG MSG MSG MSG POWER PAGE MUTE AUDIO PAGE LOUD RING IO COM SPK OUTPUT C O Phone Line DIP Switch 1 must be ON DIP Switches 1 and 5...

Страница 6: ...OR STRIKE 1 ENTRY PHONE 2 DOOR STRIKE 2 ENTRY PHONE 3 DOOR STRIKE 3 ENTRY PHONE 4 DOOR STRIKE 4 DOORBELL SWITCH AUX INPUT AUX CONTACT OUTPUT PHONE LINE INPUT LINE OUT TO PHONES ANALOG STATION INPUT ST...

Страница 7: ...double beep will indicate that you have accessed the programming mode Step 4 You can now touch tone program the features listed in section B Step 5 When finished programming hang up and move DIP switc...

Страница 8: ...es factory disabled 4 6 digits 0 9 Q 51 Q 56 Door strike 1 activation time 5 99 seconds factory set to 5 seconds 2 digits 00 99 19 Door strike 2 activation time 5 99 seconds factory set to 5 seconds 2...

Страница 9: ...Mode 3 OFF Entry Phone automatic disconnect CPC disabled Note Viking handsfree entry phones require CPC for faster automatic disconnect 3 ON Entry Phone automatic disconnect CPC enabled factory settin...

Страница 10: ...ill be called automatically answer see the Product Manual for your entry phone and begin ringing the house phones terminals 4 and 5 LINE OUT TO PHONES The house phones can then be answered door strike...

Страница 11: ...eyless codes programmed for an entry phone and not master codes If a master keyless code is entered with Global Keyless Entry enabled the C 2000B will activate the relay for the entry phone the user i...

Страница 12: ...D displays may not be compatible with certain characters Entry phone calls are factory set to ring the house phones in a custom double ring cadence 7 seconds on 3 seconds off 7 seconds on then 4 secon...

Страница 13: ...cepted when the house phones pick up and is the first digit dialed Entry Phone Caller ID and Call waiting ID 1 Entry Phone 1 2 Entry Phone 2 3 Entry Phone 3 4 Entry Phone 4 C Activating Door Strike Ga...

Страница 14: ...e designed for intermittent operation only The latch and toggle commands should NOT be used with these intermittent strikes or damage to the strike may occur Only use the latch and toggle commands wit...

Страница 15: ...odes and or manually dialing extensions K 1700 3 K 1705 3 K 1900 8 K 1700 3 BN D10 Directory Any Analog Touch Tone Phone Entry phones with built in auto dialers for phone systems without ringdown capa...

Страница 16: ...ECORDABLE TRIGGERED AUDIO CHIMES MESSAGES POWER 13 8 VAC USB LED POWER MUTE AUDIO PAGE PAGE TRIGGER OUTPUT WET 12VDC DRY N C COM N O WAVE FILE INPUT TRIGGERED AUDIO CHIME MESSAGE SELECTIONS PER TRIGGE...

Страница 17: ...16 Entry phone 1 one time use keyless entry codes factory disabled 4 6 digits 0 9 Q 11 Q 16 Entry phone 2 keyless entry codes factory disabled 4 6 digits 0 9 21 26 Entry phone 2 one time use keyless e...

Страница 18: ...ollowed by 47 If you have forgotten your security code follow the steps in Programming section A 2 Accessing the Programming Mode Locally Security Code Bypass Mode Note The security code must be six d...

Страница 19: ...QQ To disable this feature enter 57 without any preceding digits The C 2000B determines which direction the touch tone is coming from and only responds to touch tones from the called phone The factory...

Страница 20: ...he auxiliary relay during the monitor once the entry phone answers so a camera or light can be activated while monitoring Auxiliary Contact Programming DIP switch 1 OFF Enter Digits Location Auxiliary...

Страница 21: ...aximum Entry Phone Ring Count on page 20 the C 2000B stops ringing that entry phone and remains in the programming mode for up to 20 seconds ready for another C 2000B program command When the entry ph...

Страница 22: ...the relay A short buzz will indicate the door strike relay is off In this mode no caller ID data is generated by the controller and no entry phone identifier beeps are provided when the call is answe...

Страница 23: ...the door Keyless entry codes also affect the operation of the auxiliary relay contacts if the auxiliary contacts have been programmed to trigger when an entry phone has gone off hook This is when DIP...

Страница 24: ...ODUCT SOLD HEREUNDER EXCLUSIVE REMEDY AND LIMITATION OF LIABILITY WHETHER IN AN ACTION BASED ON CONTRACT TORT INCLUDING NEGLIGENCE OR STRICT LIABILITY OR ANY OTHER LEGAL THEORY ANY LIABILITY OF VIKING...

Отзывы: