18
Description
Enter Digits
+
Location
Maximum entry phone ring count (1 - 99 rings, factory set to 5 rings)
2 digits (01-99)
+
#61
Analog station ring delay (factory set to 1 ring, 00= disabled)
2 digits (00-99)
+
#63
Analog station inbound call timer (factory set to 1 minute, 00= disabled)
2 digits (00-99)
+
#64
Enable Analog Station CPC detection (factory setting)
1
+
#65
Disable Analog Station CPC detection
0
+
#65
Enable global keyless entry
1
+
#66
Disable global keyless entry. (factory setting)
0
+
#66
Security code (factory set 845464)
6 digits (0-9)
+
#47
No Entry Phone mode enabled for entry phone 1*
1
+
#81
No Entry Phone mode disabled for entry phone 1 (factory setting)
0
+
#81
No Entry Phone mode enabled for entry phone 2
1
+
#82
No Entry Phone mode disabled for entry phone 2 (factory setting)
0
+
#82
No Entry Phone mode enabled for entry phone 3
1
+
#83
No Entry Phone mode disabled for entry phone 3 (factory setting)
0
+
#83
No Entry Phone mode enabled for entry phone 4
1
+
#84
No Entry Phone mode disabled for entry phone 4 (factory setting)
0
+
#84
Enable door strike latching/toggle commands (factory setting)
Q
7
Disable door strike latching/toggle commands
Q
8
Ignore touch tones to program an entry phone
##1 - ##4
Reset all programming to factory default settings
###
Erase all keyless codes
##8
This six digit number can be used to access the programming mode. The security code has been factory set to
845464
(V-I-K-I-N-G). It is recommended that you change the security code to a personal 6 digit number. To
change the security code, access programming (see
Programming
section
A
). Enter six digits 0-9 followed by
#47
. If you have forgotten your security code, follow the steps in
Programming
section
A, 2. Accessing the
Programming Mode Locally (Security Code Bypass Mode)
.
Note:
The security code must be six digits in
length and can NOT contain a
Q
or
#
.
C. Security Code (#47)
D. Dip Switch Programming
LED3
LED1
LED2
LED4
LED5
LED6
LED7
C
C
C
C
C
C
C
J11-
1
2
3
J10-
1
2
3
J9-
1
2
3
J8-
1
2
3
J7-
1
2
3
12
3
on
4
5
VIKING
©
MODEL C-2000B
VIKING
ELECTRONICS
HUDSON, WI 54016
ADVANCED DOOR/GATE AND
ENTRY PHONE CONTROLLER
1 2 3 4 5 6 7
8 9 1 0 11 12 13
15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
PWR 13.8 V
A
C
EARTH GND
ENTR
Y
PHONE 1
DOOR STRIKE 1
ENTR
Y
PHONE 2
DOOR STRIKE 2
ENTR
Y
PHONE 3
DOOR STRIKE 3
ENTR
Y
PHONE 4
DOOR STRIKE 4
DOORBELL
SWITCH /
AUX. INPUT
AUX. CONT
ACT
OUTPUT
PHONE LINE
INPUT
LINE OUT
T
O
PHONES
ANALOG ST
A
TION
INPUT
DIP Switches shown
in the factory default
positions
OFF ON
12
3
on
4
5
14
* Note:
Viking handsfree entry phones require CPC for faster automatic disconnect.
Switch
Position Description
1
OFF
Auxiliary Contact Mode
1
ON
Doorbell Mode (factory setting)
2
OFF
Normal Operation Mode (factory setting)
2
ON
Security Code Bypass Mode
3
OFF
* Entry Phone automatic disconnect (CPC)
disabled
3
ON
Entry Phone automatic disconnect (CPC)
enabled (factory setting)
4
OFF
Entry Phone busy signal disabled
4
ON
Entry Phone busy signal enabled (factory
setting)
5
OFF
Single Line Ring Through Mode (factory
setting)
5
ON
Analog Station Dial Through Mode
* Note:
The entry phone 1 position can not be programmed in the No Entry Phone Mode while the
C-2000B
is in
the Doorbell Mode (DIP switch 1 ON, see page 18), as the Doorbell Mode relies on entry phone 1. The
C-2000B