Vi1108PS
AWG
24AW G
22AW G
20AW G 19AW G 18AW G 16AW G
mm
0,5m m
0,6m m
0,7m m
0,8m m
1,0m m
1,3m m
Ohm
52
32
20
16
13
8.2
Loop Resistance per 1,000ft (305m)
Wiring Notes
Vi1108PS & Vi1116PS Isolated power supply Installation Manual
Vi1116PS
16-Ch Power Supply
Rear View
Front View
Vi1116VPD
POWER
--
+
-
+
-
+
+
-
1
2
3
4
28 V
24 V
OFF
FUSE
LOAD
-
+
-
+
-
+
+
-
5
6
7
8
28 V
24 V
OFF
FUSE
LOAD
-
+
-
+
-
+
+
-
9
10
11
12
28 V
24 V
OFF
FUSE
LOAD
-
+
-
+
-
+
+
-
13
14
15
16
28 V
24 V
OFF
FUSE
LOAD
1.75"
19"
Vi1108PS
8-Ch Power Supply
-
+
-
+
-
+
+
-
1
2
3
4
28 V
24 V
OFF
FUSE
LOAD
-
+
-
+
-
+
+
-
5
6
7
8
28 V
24 V
OFF
FUSE
LOAD
The Vi1108PS and Vi1116PS are high quality 8-ch and16-ch fully isolated
class II power supplies that their outputs can be set individually to 24 VAC
or 28 VAC. Each power output can be individually turned on or off, is
equipped with surge protection and a 2 A glass fuse easily accessible from
front panel. The input voltage can be set to 110 VAC or 220 VAC via an
external switch.
These power supplies are 1U height and 19” rack mountable. These units
can mounted from front or rear in the rack. The output connections are
through detachable terminal blocks to ease the installation. There are one
LED for power and one LED for fault detection per output. The optional
cooling fan option can increase the aggregated current from 12 A to 16 A.
The Vi1108PS and Vi1116PS are ideal for CCTV projects or for structured
cabling environment.
• 16 isolated outputs, individually selectable to
24 VAC or 28 VAC
• 1 A max per channel, 12 A aggregated
• Built-in surge protection
• A glass fuse per channel, accessible from front panel
• Power present and fault indicator LEDs for each camera
• 19", low profile 1U wall or rack or wall mountable
• Optional cooling fans with temperature control
• Designed for structured wiring applications
• Limited Lifetime warranty
Vigitron recommends the use of 18 AWG or thicker solid wires for power
connections. Verify wire distance, camera current requirement and wire
resistance limit for the maximum distance that Power can travel. Use “Power
Distance Chart” to verify the wire distance.
-
+
-
+
-
+
+
-
Vi1116PS
Electrical
Input Voltage
110 VAC or 220 VAC, internally switch selectable
Input Current
4.8 Amps (110 VAC) / 2.4 Amps (220 VAC)
Output Voltage
Voltage: Isolated Class II, 24 V AC, off, 28V AC
Rear Panel switch selectable
Output Current:
1 A Max per camera, 12 A Max aggregated
Power:
340
VA
Fault Protection
2 A glass fuse (front access) per camera
Diagnostics LEDs No Load or Shut down: 16 Red LEDs, one per
channel
Power Present: 16 Green LEDs, one per channel
Connectors
Camera Connection: RJ-45 Connector
Data: RJ-45 Connector
Control Room Video: BNCs
Transient Immunity
per ANSI 587 C62.41
Environmental
Humidity
0 to 95%, non-condensing
Temperature
Operating: -20C to +50C
Storage: -30C to +70C
Minimum Airflow
5 ft /min
Heat 1300
BTU/hour
Mechanical
Dimensions
1.75x17x12 Inches, 4.3x43x30.5 cm (HxWxL)
Weight
22 Lb, 10 Kg
Material
Steel Sheet Metal
Features
RoHS