WARNING! - To reduce the risk of fire or electric shock, do not expose this apparatus to
rain or moisture. This apparatus shall not be exposed to dripping or splashing and no
objects filled with liquids, such as vases shall be placed on the apparatus.
WARNING! - This apparatus is a Class I product. This product must be connected to a
mains socket outlet thru an AC to DC Power supply.
WARNING! - The mains plug is used as the disconnect device and shall remain readily
operable.
Application Drawing
Vi3005
5-Port PoE Powered PoE Switch Installation Manual
DO NOT OPEN
RISK OF ELECTRIC SHOCK
CAUTION
CAUTION:
TO REDUCE THE RISK OF ELECTRICAL SHOCK,
DO NOT REMOVE COVER. NO USER SERVICEABLE
PARTS INSIDE. REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.
IP Camera-end Installation
The Smart Choice for Transmission Solutions
www.vigitron.com
Important Safety Warning
PoE Switch/PoE Midspan end Installation
- Read and keep these instructions.
- Heed all warnings.
- Follow all instructions.
- Do not use this apparatus near water.
- Clean only with a dry cloth.
- Install in accordance with the manufacturer’s instructions.
- This installation should be made by a qualified service person and should conform to all local
codes.
- DO NOT bundle UTP or Coax signals in the same conduit as high-voltage wiring.
- To reduce the risk of fire or electrical shock, do not expose these products to rain, moisture,
dripping or splashing.
- No objects filled with liquids, such as vases, shall be placed on Vigitron equipment.
- DO NOT install the unit in a place where the operating ambient temperature exceeds 75°C or
is below - 40°C.
- Make sure that the external power supply output voltage is in the recommended range.
- Do not install near any heat sources such as radiators, heat registers, stoves or other
apparatus (including DVRs) that produce heat.
- Protect the power cord from being walked on or pinched particularly at power source,
convenience receptacles, and the point where they exit from the apparatus.
- Only use attachments/accessories specified by the manufacturer.
- Unplug this apparatus during lightning storms or when unused for long periods of time.
- Refer all servicing to qualified service personnel. Servicing is required when the apparatus
has been damaged in any way, such as when a power supply cord or plug is damaged, liquid
has been spilled, objects have fallen inside the apparatus, the apparatus has been exposed
to rain or moisture, does not operate normally, or has been dropped.
- The main plug is used as the disconnect device and shall remain readily operable.
UTP Uplink w/ Remote PoE:
- Connect the network cable coming from the PoE switch or PoE midspan
to the fifth Ethernet port at rear of Vi3005.
- Plug in the IP/PoE devices to the four ports one the Vi3005's front panel.
- Set 30W/60W based on the type of the remote PoE source
PoE Power is allocated based on the required port power up to 37W starting with
Port 1 having the highest priority. Once the total sum of the PoE power is allocated
no more power will be available to remaining ports.
UTP Uplink w/ Local Power Supply:
- Connect the network cable coming from the PoE switch or PoE midspan
to the fifth Ethernet port at rear of Vi3005.
- Plug in the IP/PoE devices to the four ports one the Vi3005's front panel.
- Connect the approved local power supply to the power connector of Vi3005.
Fiber SFP Uplink:
Note: The SFP (small format pluggables) must be the same types at both ends of
the fiber cable and must match the fiber cable requirements.
- Plugin the SFP to the SFP socket of Vi3005.
- Connect the fiber cable to the SFP.
- Connect the Vi1120 power supply to the Vi3005 power connector.
Individual ports will be able to provide up to 37W. If more power needed for
approved IP devices use the Vi0015 combination cable to combine two ports.
Starting with ports 1 and 2, connect the IP device to the Ethernet port of the Vi0015
cable.
UTP link:
- Connect the network cable coming from the Vi3005 Uplink port to one of the
Ethernet ports of the PoE switch or PoE Midspan.
Fiber SFP Link:
- Connect the fiber cable to the SFP port of the network switch.
The SFP must be the same types at both ends of the fiber cable and must match
the fiber cable requirements.
The MaxiCollector Vi3005 is a revolutionary five port Port PoE switch. By
using Vigitron's Pass-Through-PoE (PTP
TM
) techology, the Vi3005 can
accept PoE power from an external source and provide PoE to all four ports.
This eliminates the need for local power supplies and outlets, and lowers
installation costs.
The Vi3005’s plug-and-play eliminates the need for IP addressing. The four
Ethernet port can be directly connected to any IP address and will pass that
device's IP address. Network pre-programmed switching features include
802.1p QoS priority queuing, port based VLAN, MAC addressing up to 2K
full and half duplex operation compliant to 802.3x standards and automatic
address learning and aging.
The Vi3005 takes full advantage of high bandwidth maintaining 10/100Mbps
transmission with minimum transmission error and latency by employing full
layer 2 network switching technology. The Vi3005 can be used to connect to
multiple remote network devices such as Megapixel IP cameras, VoIP
telephone systems, or wireless transmitters.
Using the Vi1120, 120 watt 57 volt power supply, and any MSA compliant
fiber SFP, the Vi3005 can transmit four cameras over distance of 80Km
while providing 30 watts per port and up to 60 watts for two port using the
Vi0015 combining cable.
Fiber Optic
Cat 5/6
Vi3005
PoE Cameras
Vi3005
SFP
Power
Supply
PoE Camera
PoE Camera
60W PTZ Dome
The Vi3005 is a PoE powered switch that can be used to power up to four cameras busing PoE.
The Vi3005 can be used to power up to four cameras busing PoE.
Powering the Vi3005 and 4 remote cameras using PoE
Powering the Vi3005 and 4 remote cameras using a local power supply
Vi30210
56VDC
Vi10240
Vi00016
Data +
72W PoE
328 ft. (100m)
Data +
PoE
328 ft. (100m)
Data
328 ft. (100m)
Data +
PoE
328 ft. (100m)
Data +
PoE
328 ft. (100m)
Data +
PoE
328 ft. (100m)
Non-PoE Switch
Max
ii
Net