<10. Troubleshooting>
10-2
IM 11Y01D01-01EN
No.
Displayed name
(HART)
Description
Corrective action
53 Transmission Lost
The transmission is too low to
continue measurements.
Check that the alignment is correct. Check
whether the laser beam is being blocked.
Check whether the process window is
stained. For details, see “9.1
Maintaining the Laser Beam and
54 Ref Trans Low
The reference cell transmission is
too low.
Contact your Yokogawa service
representative.
55 R Peak Height High The reference cell peak height is too
high.
Contact your Yokogawa service
representative.
57 Laser Unit Fail
The laser unit failed.
Contact your Yokogawa service
representative.
58 Inter Comm Fail
Internal communication error
occurred.
Contact your Yokogawa service
representative.
59
Laser Module Error
The laser module failed.
Contact your Yokogawa service
representative. (*1)
60 File Access Error
File access error.
Contact your Yokogawa service
representative. (*1)
61 EEPROM Error
EEPROM error.
Contact your Yokogawa service
representative. (*1)
62 LU Connect Error
An error occurred in the laser unit
connection.
Check that the laser unit connection cable is
not loose.
Contact your Yokogawa service
representative.
63 FPGA Failure
FPGA failure.
Contact your Yokogawa service
representative. (*1)
64 Program Error
Internal error occurred.
Contact your Yokogawa service
representative. (*1)
*1:
Cannot be cleared using Clear Latched Alarms. If the fault occurs again even if you restart the TDLS8000, contact your
Yokogawa service representative.
10.2 Warning Display and Handling
A warning occurs when the various types of diagnostic information being monitored by the
TDLS8000 self-diagnostics function are outside the normal range. If a warning occurs, the
TDLS8000 output and display will respond in the following manner.
• The analog output is set to the specified state (the factory default hold setting is off).
• DO digital output is generated (for the digital output wiring, see “3.2.5 Wiring Digital
• The DO LED (yellow) lights.
• The alarm indicator blinks on the YH8000 display.
• Alarm information is indicated over HART communication (see section 7.4).
• Alarm information is shown on the SCU display.
The following table shows the warning types and their corrective actions. Alarm numbers
are defined for warning type identification. These numbers are shared among the YH8000,
HART, and SCU displays, even though the abbreviations of the displayed warning names may
differ. Depending on the alarm, a sub number may also be displayed. This number is used by
Yokogawa service representatives for troubleshooting purposes.
3rd Edition: Jun. 10, 2016-00
Содержание TDLS8000
Страница 1: ...User s Manual TDLS8000 Tunable Diode Laser Spectrometer IM 11Y01D01 01EN IM 11Y01D01 01EN 3rd Edition...
Страница 10: ...ix IM 11Y01D01 01EN LT LV PL EST SLO H BG RO M CZ SK 3rd Edition Jun 10 2016 00...
Страница 25: ...Blank Page...
Страница 45: ...Blank Page...
Страница 115: ...Blank Page...
Страница 151: ...Blank Page...
Страница 231: ...Blank Page...
Страница 239: ...Blank Page...
Страница 243: ...Blank Page...
Страница 261: ...Blank Page...
Страница 303: ......
Страница 305: ......
Страница 307: ......
Страница 309: ......
Страница 311: ......
Страница 313: ...Blank Page...