LA Hardware Specification
ViewSonic LFD communcation port on the rear side:
1.
Connector type: 8P8C RJ45
2.
Pin Assignment:
Pin # Signal
Remark
1
TX+
Output from Display
2
TX-
Output from Display
3
RX+
Input to Display
4
BI_D3+
For 1G case
5
BI_D3-
For 1G case
6
RX-
Input to Display
7
BI_D4+
For 1G case
8
BI_D4-
For 1G case
frame GND
RS-232 Communication Setting
- Baud Rate Select:
9600bps (fixed)
- Data bits:
8 bits (fixed)
- Parity:
None (fixed)
- Stop Bits:
1(fixed)
LA Communication Setting
- Type:
Ethernet
- Protocol:
TCP/IP
- Port:
5000 (fixed)
- Cross subnet:
No
- Logon Credentials:
No
Command Message Reference
PC sends to LFD command packet followed by “CR”. Every time PC sends control
command to Display, the Display shall respond as follows:
1.
If the message is received correctly it will send “+” (02Bh) followed by “CR”
(00Dh)
2.
If the message is received incorrectly it will send “-” (02Dh) followed by “CR”
(00Dh)
Содержание IFP30 Series
Страница 13: ...13 I O Panel Front Left 1 1 2 3 Side Left 3 3 4 1 1 2 5 6 Bottom Left 7 1 7 8 10 11 9...
Страница 15: ...15 Remote Control 1 2 4 6 7 9 11 14 16 17 19 3 5 8 10 12 13 15 18...
Страница 45: ...45 45 Ethernet Tap Connect to toggle Ethernet on or off You can adjust Static IP and Proxy settings as well...
Страница 58: ...58 58 Advanced Adjust additional options and preferences Language Choose from the available languages...
Страница 64: ...64 64 Side Tool Bar Channel Adjust the side tool bar availability For more information see page 32...
Страница 73: ...73 73 Reset Perform a Factory Data Reset NOTE All locally stored data will be deleted...