Emissions test mode for testing flue gas with briefly
raised boiler water temperature.
Emissions test mode should be activated only by your
flue gas inspector, during the annual inspection.
1.
Set the emissions test switch on the Vitotronic 300-
K (see chapter "Starting the heating system") to
position .
The following functions are activated:
■
The pumps are started.
■
The mixers remain set to the control function.
2.
Enable the emissions test function at the control
unit of the respective boiler.
■
The burner is switched ON.
■
The boiler circuit pump starts.
Ending emissions test mode
1.
Set the emissions test switch on the Vitotronic 300-
K to position
a
.
or
Close the flap.
2.
Disable the emissions test function at the control
unit of the respective boiler.
Emissions test mode
Emissions test mode
5546 498 CA