114
Rated voltage
230 V~
Rated frequency
50 Hz
Rated current
12 A~
Power consumption
16 W
Protection class
I
IP rating
IP 20D to EN 60529; ensure through design/installation.
Function type
Type 1B to EN 60730-1
Permissible ambient temperature
■
Operation
0 to +40 °C
Installation in living spaces or boiler rooms (standard
ambient conditions)
■
Storage and transport
−
20 to +60 °C
Rated relay output breaking capacity
Plug
Component
Rated breaking
capacity
Single boiler
system
Multi boiler
system
sÖ
A1
One of the following circulation pumps:
■
Primary cylinder loading pump for cyl-
inder loading system
4 (2) A, 230 V~
X
—
■
Circulation pump for flue gas/water
heat exchanger
X
X
or
Switching output for flow rate reduction
(Therm-Control)
X
X
sA
One of the following circulation pumps:
■
Circulation pump for cylinder heating
4 (2) A, 230 V~
X
—
■
Secondary cylinder loading pump for
cylinder loading system
X
—
sL
One of the following circulation pumps:
■
Shunt pump
4 (2) A, 230 V~
X
X
■
Boiler circuit pump
X
X
■
Boiler circuit pump with butterfly valve
function
X
X
fA
Burner stage 1
6 (3) A, 230 V~
X
X
gÖ
Central fault message facility
4 (2) A, 230 V~
X
X
gS
A1
One of the following functions:
■
Motorised butterfly valve
0.2 (0.1) A, 230 V~
—
X
■
Mixing valve for return temperature
control
X
X
■
Mixing valve, heat exchanger set
X
—
lÖ
One of the following functions:
■
Burner stage 2
1 (0.5) A, 230 V~
X
X
■
Modulating burner
0.2 (0.1) A, 230 V~ X
X
Total
Max. 12 A, 230 V~