background image

3

 

Page

Table of Contents

5583 141  v1.0 

Safety

Installation

Commissioning

Operation

Troubleshooting

Additional Information

Safety, Installation and Warranty Requirements

..............2

Safety Terminology

.....................................................2

Location

....................................................................4

Installing and Connecting

.............................................5

Connecting Several Remote Control Units

......................6

Fitting the Programming Unit

.......................................7 

Removing thew programming unit (if required)

................7

Configuring the Remote Control

....................................8

Changing the Configuration During the Operation

..........8

Operation Information

..................................................9

Controls

....................................................................9

Required Settings

......................................................10

Setting the Room Temperature for Standard 
Heating Mode

..........................................................10

Setting the Heating Program

.......................................10

Comfort and Energy Saving Functions

.........................11

Rooms are too Cold

..................................................12

Rooms are too Hot

...................................................12

There is no Hot Water

...............................................12

“ Flashes in the Display

........................................12

Rotating Segments in the Display

................................12

Terminology

............................................................13

Parts List

................................................................14

Specifications

..........................................................14

Vitotrol 200A, Installation, Operating and Service

Содержание VITOTROL 200A

Страница 1: ...583 141 v1 0 10 2013 VITOTROL 200A Vitotrol 200A Remote Control Installation Operating and Service Instructions Product may not be exactly as shown Read and save these instructions for future reference IMPORTANT Certified as a component part for Viessmann boilers ...

Страница 2: ...arranty null and void Licensed professional heating contractor The installation adjustment service and maintenance of this equipment must be performed by a licensed professional heating contractor uPlease see section entitled Important Regulatory and Installation Requirements Operating and Service Documentation It is recommended that all product documentation such as parts lists operating and serv...

Страница 3: ...ogramming unit if required 7 Configuring the Remote Control 8 Changing the Configuration During the Operation 8 Operation Information 9 Controls 9 Required Settings 10 Setting the Room Temperature for Standard Heating Mode 10 Setting the Heating Program 10 Comfort and Energy Saving Functions 11 Rooms are too Cold 12 Rooms are too Hot 12 There is no Hot Water 12 Flashes in the Display 12 Rotating S...

Страница 4: ...adiator valves fully The remote unit contains a built in room temperature sensor which measures the room temperature The Room Temperature Sensor can only be used for room temperature sensing in the main living area adjusting the boiler water temperature or supply temperature to the individual room The room temperature sensor does not have any adjustment possibilities Adjustments related to the roo...

Страница 5: ...es to discharge static loads Connection Two wire communication cable 21 AWG with a maximum cable length up to 150 ft 50 m Note Never route the cable to the remote control immediately next to 120V or other high voltage cables Installation Legend A Vitotrol 200A B 2 or 3 pole plug aVG control unit or KM BUS distributor Legend A Vitotrol 200A B EA1 module C External accessory connection box Legend A ...

Страница 6: ...ied Connect in accordance with the diagram H Limit the total length of all KM BUS cables to 164 ft 50 m Legend A To the control unit see connection diagram on page 5 B Vitotrol 200A C Junction box field supplied Legend A To the control unit see connection diagram on page 5 B Vitotrol 200A C Junction box field supplied D Further BUS participants Version 2 H If several remote control units and addit...

Страница 7: ...atteries into the programming unit 1 Hook the bottom of the Vitotrol 200A interface to the mounting plate 2 Push the top of the Vitotrol 200A interface in to the mounting plate 1 Insert a flat head screwdriver into the slots along the top of the Viototrol interface and twist 2 Pull the top of the Vitotrol 200A interface out from the mounting plate 3 Unhook the base of the Vitotrol 200A interface f...

Страница 8: ...ng circuit H 3 3 OK as confirmation The operating state of the heating system is transferred Rotate the display segments this may take up to 5 min 1 Press and simultaneously at the remote control for approx 4 sec 2 With select heating circuit 1 H 1 heating circuit H 2 or heating circuit H 3 3 OK as confirmation The operating state of the heating system is transferred Rotate the display segments th...

Страница 9: ...ty mode You activate economy mode Legend A Header heating program display B Current outside temperature C Current room temperature Symbols on the display These symbols are not permanently displayed but appear subject to the system version and the operating state Heating program display in the header 9 Standby mode with frost protection w DHW heating only w Central heating and DHW heating Party mod...

Страница 10: ...ting program Factory setting 68 F 20 C Press the following keys 1 for the required set room temperature 2 OK to confirm The display shows the current room temperature actual room temperature Factory setting w for central heating and DHW heating winter mode Heating programs 9 Standby mode with frost protection w Only DHW heating summer mode w Central heating and DHW heating Press the following keys...

Страница 11: ...tting the room temperature Note This value is retained even when the party mode terminates 2 Press Ending the comfort function H Press or H Automatically after 8 hours or H Automatically when the system switches to standard heating mode in accordance with the time program selected on the Vitotronic control unit Energy saving function Economy mode select To save energy you can reduce the room tempe...

Страница 12: ...ult at the Vitotronic control unit If necessary notify your heating contractor Refer to the control unit operating instructions Remote control set incorrectly Check that DHW heating has been enabled w or w must be selected see page 10 No fuel With oil LPG Check the fuel reserves and re order if required With natural gas Open the gas shut off valve If necessary check with your gas supply utility fl...

Страница 13: ... the right temperature in line with demand is delivered to the heating circuit by the heating circuit pump The Vitotronic control unit adjusts the heating circuit flow temperature via the mixer to the various conditions e g different outside temperature Night setback See Reduced heating mode Standard heating mode When you are in the house during the day you can heat the rooms in standard heating m...

Страница 14: ...80 Installation and service instructions 081 Operating instructions Specifications Power supply via KM BUS Power consumption 0 2 W Protection class III IP rating IP 30 to EN 60529 ensure through appropriate design and installation Permissible ambient temperature H during operation 32 F to 104 F 0 to 40 C H during storage and transport 4 F to 150 F 20 to 65 C Set room temperature range 37 F to 99 F...

Страница 15: ...15 5583 141 v1 0 Vitotrol 200A Installation Operating and Service ...

Страница 16: ...Technical information subject to change without notice Printed on environmentally friendly recycled and recyclable paper Vitotrol 200A Installation Operating and Service 5583 141 v1 0 ...

Отзывы: