Viessmann VITOCONNECT OPTO2 Скачать руководство пользователя страница 7

7

Installation, service and operating instructions that are
included with the products and are available online
must be observed.
Use Vitoconnect products exclusively for monitoring,
operating and optimising systems with the user interfa-
ces and communication interfaces specified for this
purpose in the relevant printed documentation. With
regard to the communication interfaces, ensure on site
that the system requirements specified in the product
documentation are met at all times for every transfer
medium employed (e.g. required WiFi connection to a
WiFi router).

Only use the specified components for the power sup-
ply (e.g. plug-in power supply units).

Note

The devices are intended exclusively for domestic or
semi-domestic use, i.e. even users who have not had
any instruction are able to operate the devices safely.

Product information

Vitoconnect is a wall mounted internet interface for
communication with the boiler control unit of the heat
generator.
Vitoconnect enables remote control of heating systems
via the internet. Settings and checks are made via the
ViCare app.
Alternatively, the heating system can be controlled
remotely by the contractor using Vitoguide.

Vitoconnect, type OPTO2

The Vitoconnect, type OPTO2, can be used for single
boiler systems with an 

Optolink interface

.

Vitoconnect, type OT2

The Vitoconnect, type OT2, can be used for single
boiler systems with an 

OpenTherm interface

.

After commissioning Vitoconnect, type OT2, the heat
generator is operated exclusively via the ViCare app.
Room temperature settings can also be made via the
Vitotrol 100, type OT1.

Spare parts lists

Information about spare parts can be found on the
Viessmann spare parts app.

Introductory information

Intended use

 (cont.)

5834169

Information

 

Содержание VITOCONNECT OPTO2

Страница 1: ...er VIESMANN Vitoconnect Type OPTO2 Type OT2 Communication interface for remote monitoring and control of heating systems via the internet for the following user interfaces ViCare app Vitoguide VITOCON...

Страница 2: ...mmediate vicinity of opera tional wireless components Installation and adjustment All settings and work on the device must be carried out as specified in these instructions Work on electrical equipmen...

Страница 3: ...5 Connecting Vitoconnect type OT2 to heat generator 15 Connecting Vitoconnect type OT2 to Vitotrol 100 16 Closing the device and inserting it into the wall mounting bracket 16 Vitoconnect 16 Vitotrol...

Страница 4: ...ntenance Software update 25 Service 25 Cleaning 25 9 Specification 26 10 Appendix Final decommissioning and disposal of the heating system 27 11 Certification 28 12 Keyword index 29 Index Index cont 5...

Страница 5: ...plementary measures e g frost protection or moni toring for water damage Liability No liability is accepted for loss of profit unattained savings or other direct or indirect consequential losses resul...

Страница 6: ...int Do not dispose of component in domestic waste Contractor Activities that may only be carried out by the con tractor are indicated with this symbol Work on electrical equipment may only be carried...

Страница 7: ...instruction are able to operate the devices safely Product information Vitoconnect is a wall mounted internet interface for communication with the boiler control unit of the heat generator Vitoconnect...

Страница 8: ...etwork or WiFi connection K Smartphone Data connections with Vitoconnect type OT2 Only in conjunction with heat generators with an Open Therm interface M B C A G L K H F D E Fig 2 A Heat generator wit...

Страница 9: ...App Store or Google Play Store Vitoguide For contractors only Your heating system can be remotely monitored by your contractor For this your contractor requires serv ice clearance For further informa...

Страница 10: ...gard less of which control device is used Registration is automatic during commissioning via the ViCare app See page 19 Control device for the ViCare app The ViCare app supports mobile devices with th...

Страница 11: ...between transmitter and receiver WiFi signals are damped e g by air or when penetrating walls WiFi signals are reflected by metallic objects e g reinforcements in walls metal foil of thermal insula ti...

Страница 12: ...15 Heating contractors System user 15 7 Connect Vitoconnect and Vitotrol 100 Heating contractors System users 16 8 Insert Vitoconnect into wall mounting bracket Heating contractors System users 16 16...

Страница 13: ...13 Vitoconnect type OPTO2 and type OT2 1 2x 2x 2 2 Fig 3 Installation sequence Fitting the wall mounting bracket 5834169 Installation...

Страница 14: ...Only in conjunction with Vitoconnect type OT2 1 2 3 4 Fig 4 Inserting the cables Only in conjunction with Vitoconnect type OT2 1 3 2 1 Fig 5 Installation sequence Fitting the wall mounting bracket co...

Страница 15: ...Optolink interface C at the control unit of the heat generator Connection at heat generator Operating instructions for the heat generator Connecting Vitoconnect type OT2 Connecting Vitoconnect type OT...

Страница 16: ...toconnect type OT2 to Vitotrol 100 3 4 A B Fig 9 Closing the device and inserting it into the wall mounting bracket Vitoconnect 1 Fig 10 Installation sequence Connecting Vitoconnect type OT2 cont 5834...

Страница 17: ...must be near the device and freely accessi ble On site fuse protection for the socket Max 16 A US CA Max 20 A A Fig 12 1 Insert the barrel plug for the plug in power supply unit into Vitoconnect conne...

Страница 18: ...rent operating status LED indicates status of communication with WiFi server and Viessmann server LED indicates system functions and communica tion with heat generator restart update fault button actu...

Страница 19: ...ype OT2 Flashes yellow Communication error with Vitotrol 100 type OT1 See page 23 Flashes yellow quickly No connection to the heat generator See page 23 Flashes red Vitoconnect is ready to be reset to...

Страница 20: ...attempt to establish a connection has failed See chapter Troubleshooting measures Once the LED illuminates green connect the Vitoconnect to your home network again Android operating system Setting up...

Страница 21: ...when the Vito connect restarts Or Comfort mode ends automatically after 24 hours delivered condition About the ViCare app You have 2 options for ending Comfort mode via the ViCare app Tap Manual CLOS...

Страница 22: ...are subject to compliance with the rel evant licensing terms Calling up open source licences 1 Enable access point mode for the Vitoconnect See page 21 2 Call up the WiFi settings of your smartphone o...

Страница 23: ...ng Check the password during WiFi commissioning WiFi signal strength insufficient Change the installation location of the Vitoconnect See page 10 WiFi connection established but no internet connection...

Страница 24: ...ds See chapter Display and controls LED flashes red 2 Briefly press reset button B again within 5 sec onds LED is no longer illuminated The Vitoconnect restarts Setting up the WiFi after replacing the...

Страница 25: ...completed successfully the Vitoconnect will restart Note During commissioning the Vitoconnect software is automatically updated as soon as the Vitoconnect is connected to the internet Service The Vit...

Страница 26: ...e and transport 20 to 60 C Plug in power supply unit Rated voltage 100 to 240 V Rated frequency 50 60 Hz Output voltage 12 V Output current 1 A Protection class II Permissible ambient temperature Oper...

Страница 27: ...heating contractor regarding the correct disposal of your old system DE Operating fluids e g heat transfer medium can be disposed of at municipal collection points AT Operating fluids e g heat transfe...

Страница 28: ...28 Certification Certification 5834169 Appendix...

Страница 29: ...lation wall mounting bracket Vitotrol 100 type OT1 14 Installation location Vitoconnect 10 Vitotrol 100 type OT1 11 Installing wall mounting bracket Vitoconnect 13 Intended use 6 Internet access 5 Int...

Страница 30: ...5 User account 10 User registration 12 19 V ViCare app 9 Vitoguide 9 Vitotrol 100 type OT1 closing 17 W Wall mounting bracket fitting Vitotrol 100 type OT1 14 Wall mounting bracket insertion into Vito...

Страница 31: ...31 5834169...

Страница 32: ...Shropshire TF1 7YP GB Telephone 44 1952 675000 Fax 44 1952 675040 E mail info uk viessmann com Viessmann Werke GmbH Co KG D 35107 Allendorf Telephone 49 6452 70 0 Fax 49 6452 70 2780 www viessmann com...

Отзывы: