Flue location
and ventilation
Vitodens 100-W
CE-0085 BT 0029
Vitodens 200-W
CE-0085 BR 0432
Vitodens 222-F
CE-0085 BR 0433
Vitodens 242-F
CE-0085 BO 0338
Vitodens 111-W
CE-0085 BT 0029
Please note
This is to confirm that the flue system
is approved to Building Regulations and
certified to the appropriate EC Gas
Equipment Directive. Manufacturers
instructions must not be taken in any
way as overriding statutory obligations.
System Certification
System certification to DVGW-VP 113 and
EC Gas Equipment Directive 90/396/EEC
in conjunction with PPs flue pipes offered
by Skoberne.
Statutory requirements
The appliance is suitable only for installation
in GB and IE and should be installed in
accordance with the rules in force. In GB a Gas
Safe Registered installer must carry out the
installation. It must be carried out in accordance
with the relevant requirements of the – Gas
safety (installation and use) regulations (current
issue). It is in your own interest and safety to
ensure that the law is complied with.
In addition to the above regulations, this
appliance must be installed in accordance
with the current IEE Wiring Regulations for
electrical installation (BS 7671), local Building
Regulations, the Building Standards (Scotland)
(Consolidation) Regulations, bye laws of the
local water undertaking and Health and Safety
Document NO. 635 'The Electricity at Work
regulations 1989' In Ireland (IE), the installation
must be carried out by a Competent Person
and installed in accordance with the current
edition of I.S.813 "Domestic Gas Installations",
the current Building Regulations and references
should be made to the current ETCI rules for
electrical installation.
It should also be in accordance with the relevant
recommendations in the current editions of
the following British Standards and Codes of
Practice: BS 5449, BS 5546, BS 5440:1, BS
5440:2, BS 6798, BS 7593, BS 6891, IGE/UP/7
and IS 813 for IE.
All Registered installers are required to notify
building control when they have installed or
exchanged a gas appliance in a residential
dwelling. This can be done via Gas Safe.
Boiler Position
The following limitations must be observed
when siting the boiler:
The boiler is not suitable for external
installation. The position selected for the
installation should be within the building,
unless otherwise protected by a suitable
enclosure and must allow adequate space
for installation, servicing and operation
of the appliance and for air circulation
around it.
The position must allow for a suitable flue
system and terminal position. The boiler
must be installed on a flat vertical
wall capable of supporting the weight of
the appliance and any ancillary equipment
when full.
Due consideration should be given to the
routing of the condensate drain from the
chosen position.
If the boiler is to be fitted in a timber
framed building it should be fitted in
accordance with ige/up/7. If in doubt
advice must be sought from the Institute
of Gas Engineers.
General boiler installation requirements
If the appliance is to be installed in a room
containing a bath or shower, any electrical
switch or control utilising mains electricity
must be so situated that it cannot be
touched by a person using the bath or
shower. Attention is drawn to the
requirements of BS 7671 (the current
I.E.E Wiring Regulations) and in Scotland
the electrical provisions of the Building
Regulations applicable in Scotland.
A compartment used to enclose the
appliance must be designed and
constructed specifically for this purpose.
An existing cupboard or compartment may
be used provided it is modified accordingly.
BS 7698:2000 gives details of the essential
features of cupboard/compartment
design, including airing cupboards. The
Vitodens range does not require
compartment ventilation.
Where installation will be in an unusual
location, special procedures may be
necessary. BS 6798 gives detailed
guidance on this subject.
General installation