Pump curves
0
0.5
1.0
1.5
Pump rate in m³/h
Head
0
20
40
60
80
2.0
A
B
Pump rate in l/min
0
8.3
16.7
25
33.2
kPa
0
200
400
600
800
mbar
High efficiency circulation pump, types PS10 and P10
A
Pressure drop curve
B
Max. head
Pump rate in m³/h
Head
2.0
Pump rate in l/min
0
8.3
16.7
25
33.2
0
0.5
1.0
1.5
0
20
40
60
80
2.5
41.7
200
400
600
800
kPa
0
mbar
A
B
High efficiency circulation pump, types PS20 and P20
A
Pressure drop curve
B
Max. head
Heat meter
Part no. Z013 684
For solar thermal systems with "Typfocor LS" heat transfer medium
■ For wall mounting in conjunction with Solar-Divicon, type PS10
■ For installation on DHW cylinder with fitted Solar-Divicon, type
PS10
■ Capture of flow and return temperatures
■ Capture of flow rate, nominal flow rate 1.5 m³/h
■ Indication of energy amount, heating output, flow rate, flow and
return temperatures
Solar safety valve 8 bar
In solar thermal systems, the 6 bar safety valves fitted at the factory
can be replaced with 8 bar safety valves.
Installation accessories
(cont.)
86
VIESMANN
VITOSOL
8
5822 440 GB