Vitocal 350-A, type AWH-I, AWH-O
Air/water heat pump without integral circulation pump (secondary pump) and without
three-way diverter valve. A secondary pump assembly (secondary pump and circu-
lation pump for cylinder heating) is available as an accessory.
The four red cores in the heat pump control unit must be removed for the external
circulation pumps to be connected (see page 82).
General information - electrical connection
■ The total output of all components con-
nected directly to the heat pump con-
trol unit (e.g. pumps, valves, message
facilities, contactors) must not exceed
1000 W.
If the total output
≤
1000 W, the indi-
vidual rating of a component (e.g.
pump, valve, message facility, contac-
tor) can be greater than specified (see
page 245).
■ If two components are connected to
the same terminal, press both cores
together into a
single
wire ferrule.
■ If the compressor and/or instantane-
ous heating water heater (accessory)
are operated at a lower tariff (power-
OFF), provide an additional cable for
the power-OFF signal (e.g. NYM 3 x
1.5 mm
2
) from the distribution board
(meter box) to the heat pump control
unit (see page 105).
■ The number of power cables from the
distribution board (meter box) to the
heat pump control unit and to the con-
trol panel depends on the system ver-
sion and tariffs used (see from
page 104).
■ The cores of the KM BUS cable are
interchangeable.
For further information, see control panel
(page 70), heat pump control unit
(page 75) and power supply
(page 104).
Internal heat pump, type AWH-I
!
Please note
Avoid damaging the appliance
during handling.
Never
put weight on the top, front
or side panels of the appliance.
!
Please note
Installing a compressor at a steep
angle inside the heat pump can
result in equipment damage.
Preparing for installation
Product information
5414 828 GB
Содержание VITOCAL 350-A
Страница 54: ...54 5 3x 7 6 3x 3x 3x Installation sequence Fitting the outer panels cont 5414 828 GB ...
Страница 57: ...57 3x 8 9 3x 3x 3x Installation sequence Fitting the outer panels cont 5414 828 GB Installation ...
Страница 58: ...58 2x 10 11 3x 3x Installation sequence Fitting the outer panels cont 5414 828 GB ...
Страница 60: ...60 4 mm 4x 4x 4x 3 2 1 2 2 Installation sequence Fitting the silencer hoods only type AWH O 5414 828 GB ...
Страница 62: ...62 Type AWH I 1 Installation sequence Installing the heat pump cont 5414 828 GB ...
Страница 63: ...63 Type AWH O 2 3 4 5 4x 1 Installation sequence Installing the heat pump cont 5414 828 GB Installation ...
Страница 115: ...115 Fitting the front panel 1 2 Installation sequence Closing the heat pump cont 5414 828 GB Installation ...
Страница 227: ...227 053 032 039 034 038 033 034 039 040 027 Parts lists Parts list type AWH I cont 5414 828 GB Service ...
Страница 228: ...228 052 054 059 008 056 025 020 Parts lists Parts list type AWH I cont 5414 828 GB ...
Страница 236: ...236 053 032 039 034 038 033 034 039 027 Parts lists Parts list type AWH O cont 5414 828 GB ...
Страница 237: ...237 052 054 059 008 055 025 020 Parts lists Parts list type AWH O cont 5414 828 GB Service ...