Viessmann ViCare Скачать руководство пользователя страница 1

Operating instructions

for the system user

VIESMANN

ViCare thermostatic radiator valve

Radiator actuator for individual room control

ViCare thermostatic radiator valve

6155182 GB

5/2019

Please keep safe.

Содержание ViCare

Страница 1: ...Operating instructions for the system user VIESMANN ViCare thermostatic radiator valve Radiator actuator for individual room control ViCare thermostatic radiator valve 6155182 GB 5 2019 Please keep safe ...

Страница 2: ...ere with electronic medical devices particularly pacemakers hearing aids and defibrillators If any such equipment is fitted users should avoid being in the immediate vicinity of operational wireless components Installation and adjustment All settings and work on the device must be carried out as specified in these instructions Observe minimum clearances to ensure reliable signal transmission Opera...

Страница 3: ...3 Auxiliary components and individual parts For replacement use only spare parts supplied or approved by Viessmann Safety instructions Safety instructions cont 6155182 ...

Страница 4: ... thermostat 12 5 Commissioning Display and controls 13 Shown on display 13 Standby display 14 Pairing the ViCare thermostatic radiator valve 14 6 Settings Restoring factory settings 15 7 What to do if The display flashes 16 flashes 16 is illuminated continuously 16 is displayed 16 and are displayed 16 is displayed 16 is displayed 17 is displayed 17 All displays are off 17 Further information on fa...

Страница 5: ... fulfilment of which is essential for proper execution of the contract The limitation of liability shall not apply if the damage was caused deliberately or through gross negligence or if mandatory liability applies due to product liability legislation The Viessmann General Terms and Conditions apply which are included in each current Viessmann price list Viessmann accepts no liability for push not...

Страница 6: ...pported Viessmann heat and power generators Also take account of the relevant installation service and operat ing instructions In particular observe the current and voltage specifica tions for connections and hook ups The ViCare thermostatic radiator valve is designed exclusively for operation as a standalone device or for operation in conjunction with a gateway e g Vitocon nect type OPTO2 In conn...

Страница 7: ...f the ViCare thermostatic radiator valve is switched on every 7 days Current information about the ViCare thermostatic radiator valve For a current overview of supported gateways or updates for the product e g information on commis sioning See www vicare info Data connections with gateway K A E H G F D B C Fig 1 A Gateway e g Vitoconnect type OPTO2 or type OT2 B Low power radio C ViCare thermostat...

Страница 8: ...ignals are reflected by metallic objects e g reinforcements embedded in walls metal foil of thermal insulation and thermal glazing with metal lised thermal vapour deposit Wireless signals are isolated by service ducts and lift shafts Wireless signals are disrupted by devices that also operate with high frequency signals Maintain a dis tance of at least 2 m from these devices Computers Audio and vi...

Страница 9: ...ir the ViCare thermostatic radiator valve 14 5 Fit and set up the ViCare thermostatic radiator valve on the connection adaptor 12 12 Fitting the connection adaptor Note The valve must be wide open before the old radiator actuator is removed To do this turn the actuator to the highest level Installation sequence Overview of the installation and commissioning process 6155182 Installation ...

Страница 10: ...10 O O RA M30 RAV RAVL 2 1 2 1 1 1 2 2 Fig 4 Installation sequence Fitting the connection adaptor cont 6155182 Installation ...

Страница 11: ...g 6 2 Insert the batteries Shown on display Delivered condition is shown Installation mode is active Replace the batteries The set room temperature is displayed Note Do not use rechargeable batteries Installation sequence Opening the thermostat 6155182 Installation ...

Страница 12: ... ensure the display A is facing upwards 3 Press button B for at least 3 seconds to close the thermostatic valve Shown on display The set room temperature is displayed 5 Set the required set room temperature by turning thermostatic head C Installation sequence Fitting and setting up the thermostat 6155182 Installation ...

Страница 13: ...de Battery charge level For further information See page 16 Status of the wireless connection Illuminated continuously The wireless connection is active Flashing The wireless connection has been interrupted Flashing quickly The wireless connection is being established Note Flashing The LED comes on once per second Flashing rapidly The LED comes on twice per second Note If the wireless connection b...

Страница 14: ...code A on the thermostat 4 Pairing process Note The pairing process is only possible in installation mode If the thermostat is not in installation mode press operating button B for approx 3 seconds until is displayed Briefly press operating button B flashes Shown on display Successful is illuminated continuously and flashes Installation mode is active Failed appears Repeat the pairing process 5 Fi...

Страница 15: ...messages and settings are reset A 3 2 4 Fig 11 1 Open the thermostat See page 11 3 Press and hold operating button A Insert the bat tery at the same time Shown on display All displays are illuminated for about 2 seconds is then shown Installation mode is active Settings Restoring factory settings 6155182 Functions ...

Страница 16: ...ven if the temperature has not risen If you change the current set room temperature the function is automatically switched off If the room temperature falls below 8 C the frost protection function is activated and the open window detection function is switched off and are displayed Only in conjunction with a gateway Cause Remedy Open window detection function is switch ed on No action required If ...

Страница 17: ...e thermostatic radiator valve if necessary All displays are off Cause Remedy Standby display Turn the thermostatic head to activate the display The batteries of the thermostatic radiator valve have run out Replace the batteries See page 11 Software or hardware fault Replace the ViCare thermostatic radiator valve if necessary Further information on fault messages See the ViCare app What to do if is...

Страница 18: ... Cleaning The surfaces of the thermostat can be cleaned with a microfibre cloth Maintenance battery replacement The ViCare thermostatic radiator valve is mainte nance free If the batteries need replacing this will be indicated on the thermostat display See page 16 Note Replacing the batteries See page 11 Maintenance Software update 6155182 Maintenance ...

Страница 19: ... i r p Transmission interval Every 7 5 s Protection class III IP rating IP 20D to EN 60529 ensure through design installation Normal range 8 to 30 C Rated lift range 4 2 mm Valve control force 70 N Connection M 30 x 1 5 Adaptor for Danfoss RAV RA RAVL included in standard delivery Permissible ambient temperature Operation 0 to 40 C Installation in living spaces or boiler rooms standard ambient con...

Страница 20: ...tem Viessmann products can be recycled Components and fluids from your heating system do not belong in ordinary domestic waste Please speak to your contractor about the correct dis posal of your old system DE Operating fluids e g heat transfer medium can be disposed of at municipal collection points AT Operating fluids e g heat transfer medium can be disposed of at municipal collection points ASZ ...

Страница 21: ... 12 Installation location 8 Intended use 6 L Liability 5 M Maintenance 18 N Network 7 Network operator 5 O Operation 7 P Pairing the thermostat 14 Permissible ambient temperatures 19 Product information 7 R Range WiFi connections 8 Remote control 7 Remote monitoring 7 Replacing the batteries 11 S Shown on display 13 Software update 18 Specification 19 Standby display 14 Supported gateways 7 T Term...

Страница 22: ...22 6155182 ...

Страница 23: ...23 6155182 ...

Страница 24: ... Shropshire TF1 7YP GB Telephone 44 1952 675000 Fax 44 1952 675040 E mail info uk viessmann com Viessmann Werke GmbH Co KG D 35107 Allendorf Telephone 49 6452 70 0 Fax 49 6452 70 2780 www viessmann com 6155182 Subject to technical modifications ...

Отзывы: