75
Danger
Risk of crushing or entanglement due to rotating
and moving parts.
Do not reach in through the maintenance cov-
ers.
Do not remove any protective covers.
Check the limit position of the rotary grate by the fol-
lowing visual inspections:
■
The grate must be horizontal in the end position.
■
The gap between the grid elements must not be too
large.
1.
2.
3.
4.
Fig. 57
1.
Remove casing panel.
2.
Open the grate maintenance cover.
3.
Clean the grate with the scraper (accessory).
4.
Check the grate end position.
Note
The grate elements must be horizontal in the end
position.
Check the grate limit switch if applicable.
Commissioning, inspection, maintenance
Checking the grate end position and cleaning
5679249