Incorrect usage or operation of the appliance (e.g. the
appliance being opened by the system user) is prohibi-
ted and will result in an exclusion of liability. Incorrect
usage also occurs if the components in the heating
system are modified from their intended function.
Note
The appliance is intended exclusively for domestic
use, i.e. even users who have not had any instruction
are able to operate the appliance safely.
Product information
Vitocal 060-A
A DHW cylinder is integrated into the type T0E-ze
DHW heat pump.
The heat pump uses the thermal energy in the indoor
or outdoor air for DHW heating.
At times of peak DHW demand, an immersion heater
can provide reheating (fitted at the factory for type
T0E-ze; accessory for type T0S-ze).
Type T0S-ze contains the full function range of type
T0E-ze. In addition, a solar thermal system or external
heat generator (e.g. oil/gas boiler) can be connected.
The heat pump is available for
recirculation air
mode
,
outdoor air mode
and
recirculation air mode
with air discharge to the outside
.
Recirculation air mode
In recirculation air mode, the ambient temperature
(indoor air in the installation room) is used for DHW
heating.
When DHW is being heated, the installation room is
cooled and dehumidified.
Recirculation air mode with air discharge to the
outside
Ambient air is supplied to the DHW heat pump. A sep-
arate outdoor air aperture simultaneously allows out-
door air to enter the room.
The ambient air that is cooled down during DHW heat-
ing is routed outdoors by the DHW heat pump.
Outdoor air mode
In outdoor air mode, outdoor air is supplied via a duct.
The outdoor air that is cooled down during DHW heat-
ing is routed outdoors by the DHW heat pump.
Outside temperature limits
Note
What DHW temperature the heat pump can achieve
depends on the outside temperature.
The maximum achieved is 62 °C.
Information
Intended use
(cont.)
6136003