Collector clearance 21 mm
C
Collector connection
D
Type plate
10.
Between the 2nd and 3rd collector support and
between the 4th and 5th, etc., screw joining plate
7
at the top
onto the clamping bracket.
Fitting the connection set and collector temperature sensor
Installing the locking ring fitting
■
All pipes must be cut at right angles and deburred.
■
Push the union nut and the locking ring onto the pipe
and lightly lubricate the threads with oil.
■
Push the pipe into the locking ring fitting as far as it
will go.
■
Initially tighten union nut by hand, then tighten with
an open-ended spanner by a further
¾
revolution.
!
Please note
Connection pipes and plugs must not display
any damage.
Lubricate O-rings
only
with the special valve
grease provided.
Never
fit annealed copper pipes onto the locking ring
fittings.
Installing the collector
(cont.)
5727 904 GB