Data sheet
Burner System Loader System
PYROMAT-DYN
1
Köb Holzheizsysteme GmbH, Flotzbachstr. 33, A-6922 Wolfurt, Tel. +43/5574/6770-0, Fax 65707, E-Mail: [email protected]
Subject to technical changes
3010-5
2009-03-01_GB
Table of dimensions
:
Pyromat-DYN [Art. No.]
KPM-DYN_45
KPM-DYN_65
KPM-DYN_85
I
Forward flow, connection Bsp
R 1¼“
R 1¼“
R 1½“
II
Return flow, connection Bsp
R 1¼“
R 1¼“
R 1½“
III
Safety valve connection Bsp
R ½“
R ½“
R ½“
IV
Sensor for run-off safety valve
connection Bsp
R ½“
R ½“
R ½“
V
Drain valve
R ½“
R ½“
R ½“
VI
Inspection window (transport hook) connection Bsp
R 1“
R 1“
R 1“
A
Height of casing
1430
1490
1490
B
Width of casing (dismantled)
795 (686)
795 (686)
795 (686)
C
Length of casing
958
1163
1313
D
Length of exhaust fan
500 500
630
E Filling
height
1134
1134
1134
F
Height of lid, open
1892
2012
2012
G
Radius of ash door
365
365
365
H Outlet,
burner
265
265
265
J
Outlet, exhaust fan
175
175
300
M
Flange, forward flow, burner
1331
1389
1386
N
Flange, return flow, burner
811
869
693
O
Space for operation
800
800
800
P
Min. distance to wall
100
100
100
S
Connection for exhaust fan 1)
200
200
200
T
Width of firebox
550
550
550
U
Depth of firebox
300
400
400
W
Outlet, exhaust fan
293
293
293
Z
Slide-in module flange
650
765
800
a
Connection, burner
108
108
108
b
Connection, burner
214
214
214
c
Connection, burner
183
183
183
Operation and maintenance
1 Firebox
door
2
Ash pan door
3
Cleaning door, top
4
Cleaning door, bottom (slide-in module side)
5
Maintenance lid to radiation chamber
6
Maintenance lid to combustion chamber, automatic (opposite slide-in module)
Electric drives, burner [Art. No. KPM-DYN-..]
10 Drive, de-ashing / Cleaning (opposite slide-in module)
11 Motor-driven air vent (primary and secondary)
12 Motor for exhaust fan
13 Burner
pump
14 Burner control valve with servomotor
Electric connections and sensors, burner
21 Burner
sensor
22 Return flow sensor
23 Exhaust gas sensor
24 Lambda
sensor
25 Burner control panel with temperature-limiting safety switch
26 Sockets for electrical connection
Electric drives and sensors, slide-in module
31 Drive for feed auger
32 Light barrier for metering container
33 Light barrier for combustion chamber
34 Temperature sensor for feed auger
35 Ignition
device
1