6.4 Annexes
Function ECO-N
The pipeline will suffer a drop in temperature commensurate with the weather-led
heating control. The charging of the utility water heater is carried out with the maximum
set supply temperature.
To do this the hot water is diverted by a valve to the utility water heater. This is
extended to ancillary time periods by the integrated timer, whereby the room unit will be
interrupted for a short time.
Adjustable parameters
Screen
number
Parameters
Factory setting
01 Operating
mode:
Operating mode selection.
Off
The room unit is switched off.
Day / Night
The room unit is controlled in accordance
with a timer program. By day controlled with
normal temperature, by night with a reduced
temperature.
Day / Off
The room unit is controlled in accordance
with a timer program. By day controlled with
normal temperature, by night the room unit is
switched off.
Day
Permanent normal temperature.
Night
Permanent reduced temperature.
Manual
The pump is switched on, the valve is not
controlled.
L
Use this setting only for emergency
operation if a fault message is shown on the
display.
1. Inform your heating specialists for further
instructions on fault rectification.
Day / night
02
Number of heating periods:
The week program is entered in the form of
heating periods. Each week program comprises
heating days, start and end.
There are a maximum of 7 heating periods
available.
1
03
Heating period 1, heating day:
Day or days for which the switching times are to
be applied. The heating days are selected with
keys F1 (for Monday) to F7 (for Sunday).
One button press
Æ
day selected, one further
button press
Æ
day deselected.
L
This setting is only available with day / night
or day / off operating modes.
Mon to Sun