Fig. 2
A
Living room or bedroom
B
Installation room
C
Exhaust air
D
Outdoor and exhaust air duct
E
Outdoor air
F
Ventilation unit
G
EPP pipe
H
Extract air
K
Round duct connection piece
L
Flat duct connection piece
M
Air distribution box
N
Supply air
Supply air/extract air valves
■
Arrange the supply air and extract air valves in the
room geometry so that the air is routed as directly as
possible between rooms that are ventilated and
those from which air is extracted. At the same time,
ensure as broad a flow pattern as possible through
the entire room.
■
Max. distance to the ceiling in the case of wall
mounting: 300 mm
Air routing between rooms
■
Create an interconnected room air supply between
the rooms to be ventilated and those from which air
is to be extracted.
■
For this, a gap under doors into the apartment is suf-
ficient. The correlation between gap height and air
flow rate is shown in DIN 1946-6 (see technical
guide).
■
Where internal doors are tightly sealed, provide on-
site noise attenuated overflow vents in the internal
walls or in part of the door.
Preparing for installation
Supply air and extract air ducts
(cont.)